BlackDiamond 8800 Series
Àü¹®ÈµÈ
³×Æ®¿öÅ© ÀÎÇÁ¶ó ¼Ö·ç¼ÇÀ¸·Î, ±â¾÷ IT °ü¸®ÀÚµéÀº °úµµÇÑ º¹À⼺À¸·Î ½Ã°£°ú ¸®¼Ò½º¸¦ ¼Ò¿äÇÒ ÇÊ¿ä°¡ ¾ø´Ù. Extreme
Networks® ÀÇ BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °ü¸® overhead, ¿î¿µ»óÀÇ º¹À⼺°ú
ÁöÃâ°æºñ¸¦ ÁÙ¿©ÁÖ´Â Çö´ë½ÄÀÇ two-tier ³×Æ®¿öÅ©¸¦ °¡Áø ÀüÅëÀûÀÇ three-tier ±¸Á¶·Î ´ëü½ÃÅ°¸ç ±â¾÷ÀÇ
architecture ¸¦ ÀçÁ¤ÀÇÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ¾ðÁ¦ ¾îµð¿¡¼³ª voice-class
À̿뼺, °í¹Ðµµ PoE, ±â°¡ºñÆ® ÀÌ´õ³Ý°ú 10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» Àü´ÞÇÑ´Ù. °¡Àå ÁÖÀÇ°¡ ÇÊ¿äÇÑ ±â¾÷ ½ºÀ§ÄªÀÇ edge(Enhanced
Data GSM Environment)¿¡ ÀûÇÕÇÏ´Ù.(Voice-over-IP (VoIP), video, wireless,
traffic) non-blocking Æ÷Æ®´Â High Performance Cluster Computing (HPCC)
À» À§ÇØ ¼öõ°³ÀÇ ¼¹ö¸¦ »óÈ£¿¬°áÇÑ´Ù. ±¤¹üÀ§ÇÑ º¸¾ÈƯ¡À¸·Î BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Áß°ß±â¾÷À»
À§ÇÑ ´ÜÀϽºÀ§Ä¡ ¼Ö·ç¼ÇÀÌ µÉ¼öµµÀÖ´Ù. full range of Layers 2 - 4 Ư¡Àº ÇÏ´Ü°ú Áß¾Ó »çÀÌÀÇ Ã¼ÁõÀ»
°æ°¨½ÃÅ°¸ç ÃÊ°í¼Ó ¿¬°áÀÇ ÁýÇÕÀ» Çã¿ëÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ÇöÀçÀÇ IPv6 ¿Í Â÷¼¼´ë
±â¾÷À» À§ÇØ ÁغñÁßÀÌ´Ù.
|
|
Target
Applications
- À¯,
¹«¼±, IP ÅÚ·¹Æ÷´Ï ÅëÇÕÀ» À§ÇÑ °í¹Ðµµ PoE edge ½ºÀ§Ä¡
- High
Performance Cluster (HPCC) ¸¦ À§ÇÑ ³·Àº ´ë±â½Ã°£ Á¢¼ÓÀ» Á¦°øÇÏ´Â »óÈ£¿¬°á ½ºÀ§Ä¡
- ÁßÇü
³×Æ®¿öÅ©·ÎÀÇ ´ÜÀÏ ½ºÀ§Ä¡ ³×Æ®¿öÅ© ¼Ö·ç¼Ç
- ÀüÅëÀûÀÎ
±â°¡ºñÆ®³ª 10±â°¡ºñÆ® ÀÌ´õ³Ý ÁýÇÕ½ºÀ§Ä¡
Voice-Class
Availability
- ÃæºÐÇÑ
½Ã½ºÅÛ µðÀÚÀÎ
- Modular
ExtremeXOS¢â Operating System (OS) for non-stop operations
- ÀÌ´õ³Ý
ÀÚµ¿º¸È£ ½ºÀ§Äª(EAPS) ź·ÂÀûÀÎ ÇÁ·ÎÅäÄÝ
High-Performance
Connectivy
- Voice
and wireless connectivity
- 570
Mpps ¸¦ Áö¿øÇÏ´Â ´ëÇü½ºÀ§Äª ´É·Â
- ´Ù¼ö
¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ Åº·ÂÀûÀÎ Á¢¼Ó¼º
Comprehensive
Security Providing Defense-In-Depth
- Directory-integrated
link security
- ³×Æ®¿öÅ©
ħÀÔ¿¡ ÀÀ´ëÇϴ ħÀÔÂ÷´Ü ÀÀ´ë
- °ÈµÈ
³×Æ®¿öÅ© ÀÎÇÁ¶ó
Voice-Class
Availability
°í¼öÇà
³×Æ®¿öÅ© Á¢¼ÓÀ¸·Î, Á¢¼Ó·¹À̾¼ pc¿Í IP ÅÚ·¹Æ÷´Ï¿¡ ¿¬°áÇϰųª Ŭ·¯½ºÅÍ »ó¿¡¼ ¼¹öµéÀ» »óÈ£¿¬°á ÇÏ´øÁö °£¿¡ ¸Å¿ì
À¯¿ëÇÏ´Ù.
BlackDiamond 8800 modular ½ºÀ§Äª
±ºÀº ±¤º¡À§ÇÑ Çϵå¿þ¾î redundancy(Áߺ¹) ¿Í ÁýÇÕ ¾îÇø®ÄÉÀ̼ǿ¡ ¿ä±¸µÇ´Â
³×Æ®¿öÅ©
º¹±¸¸¦ Á¦°øÇÏ´Â modular OS¢âExtremeXOS¢â
¸¦ ÅëÇÕÇÏ¿´´Ù.
Redundant
System Design
Redundant
Management Modules
BlackDiamond
8800 modular ½ºÀ§Äª ±ºÀº °ü¸®½ºÀ§Ä¡ ¸ðµâ(MSM) ÀÌ ¿À·ù°¡ ¹ß»ýÇÑ´Ù¸é, second MSM ÀÌ ÀÚµ¿ÀûÀ¸·Î Àüü½ºÀ§Ä¡ÀÇ
°ü¸®Ã¥ÀÓÀ»
Àμö¹Þ±âÀ§ÇØ
ÀÚµ¿ ´ëüÀÛµ¿ mechanism À¸·Î ±¸¼ºµÇ¾îÀÖ´Ù. ÀÌƯ¡Àº
À½¼º°ú mission-critical ¾îÇø®ÄÉÀ̼ÇÀ» ¿î¿µÇÏ´Â ³×Æ®¿öÅ©¿¡ ÇʼöÀûÀÌ´Ù.
Advanced
Chassis Design for Availability
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °í¸³µÈ Á¦¾î¿Í data plane, ÆÄ¿öºÐ¹è¸¦ À§ÇÑ redundant controller ¿Í fan
control, ³×Æ®¿öÅ©¿¡ ¿µÇâÀ»
¹ÌÄ¡±âÀü¿¡
¾ÇÀÇÁ¢ Á¢¼ÓÀ» ½Äº°Çϴ ȯ°æ ¸ð´ÏÅ͸µ °°Àº °íÀ̿뼺 ¼³°è¿ä¼Ò¿¡
ÀÇÇØ ÀÌÇàµÇ´Â passive backplane À» Æ÷ÇÔÇÑ´Ù.
Redundant
Load Sharing Power Supplies
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 6°³ÀÇ ³»ºÎ ÆÄ¿ö ¼ÇöóÀ̸¦ µ¿½Ã¿¡ °øÀ¯ÇÏ¿© ·ÎµåÇÒ¼öÀÖ´Â ¿©À¯ÀÖ´Â ÆÄ¿ö ȯ°æ¼³Á¤À» Áö¿øÇÑ´Ù.
2
+1 ȯ°æ¼³Á¤ÀÇ 3°³ÀÇ ÆÄ¿ö ¼ÇöóÀÌ´Â ±â°¡ºñÆ®³ª 10 ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®·Î ¸ðµÎ ÀûÀçµÈ chassis ·Î °ø±ÞÇÒ¼öÀÖ´Ù.
µ¡ºÙ¿©¼,
¿ÜºÎÆÄ¿ö Æ®·¹À̸¦ ÇÊ¿ä·Î ÇÏÁö¾Ê°í, 3°³ÀÇ ÆÄ¿ö¼ÇöóÀÌ´Â Ä¿´Ù¶õ PoE ±¸ÇöÀ» Áö¿øÇϱâ À§ÇØ ÀÌ¿ë°¡´ÉÇÏ´Ù.
Redundant
Cooling Fans in a Hot-Swappable Fan Tray
A
tray of nine/six fans Àº BlackDiamond 8800 ½Ã¸®Áî »þ½Ã¿¡¼ ÃæºÐÇÑ cooling À» Àü´ÞÇÑ´Ù.
fan
tray ÀÚü°¡ hot swappable À̶ó¼, BlackDiamond 8800 ½Ã¸®Áî ½Ã½ºÅÛÀº fan tray ±³Ã¼µÇ´Â µ¿¾È¿¡µµ
¿î¿µÀÌ Áö¼ÓµÈ´Ù.
Modular
Operating System for Non-stop Operations
True
Preemptive Multitasking and Protected Memory
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °¢±â·ÎºÎÅÍ º¸È£µÇ´Â ºÐ¸®µÈ OS ÇÁ·Î¼¼½º¿¡¼ ¿î¿µÇϱâÀ§ÇÑ OSPF ¿Í ½ºÆÐ´× Æ®¸®°°Àº °¢±â ¸¹Àº
¾îÇø®ÄÉÀ̼ÇÀ»
Çã¿ëÇÑ´Ù. ÀÌ°ÍÀº Çâ»óµÈ ½Ã½ºÅÛ ¹«°á¼º°ú DoS °ø°ÝÀ¸·ÎºÎÅÍ
°íÀ¯ÀÇ ¹æ¾î¸¦ °¡Á®¿Â´Ù.
Process
Monitoring and Restart
ExtremeXOS
´Â process ¸ð´ÏÅ͸µ°ú restart ¸¦ ÀÌ¿ëÇÏ¿© ³×Æ®¿öÅ© À̿뼺À» Áõ°¡½ÃŲ´Ù.
°¢±â
µ¶¸³ÀûÀÎ OS ÇÁ·Î¼¼½º´Â ½Ç½Ã°£À¸·Î °¨½ÃµÈ´Ù. ¸¸¾à ÇÁ·Î¼¼½º°¡ ¹ÝÀÀÀÌ ¾ø°Å³ª ¿î¿µÀÌ ÁßÁöµÈ´Ù¸é, ÀÚµ¿À¸·Î Àç½ÃÀ۵ȴÙ.
Loadable
Software Modules
ExtremeXOS
ÀÇ ¸ðµâ·¯ ¼³°è´Â ³×Æ®¿öÅ©¿¡¼ ³ôÀº À̿뼺À» °¡Á®´ÙÁÖ´Â °³º°Àû ¼ÒÇÁÆ®¿þ¾î ¸ðµâÀÇ ¾÷±×·¹À̵带 Çã¿ëÇÑ´Ù.
High
Availability Network Protocols
Ethernet
Automatic Protection Switching (EAPS)
EAPS
´Â ÀüÅëÀû À½¼º ³×Æ®¿öÅ©·Î ºÎÅÍÀÇ À¯ÀúµéÀÌ ±â´ëÇϴ ź·Â¼º°ú ÀÛ¾÷½Ã°£ÀÇ ·¹º§À» Á¦°øÇÏ´Â IP ³×Æ®¿öÅ©¸¦ Á¦°øÇÑ´Ù.
EAPS
´Â ½ºÆд×Æ®¸®³ª Rapid ½ºÆд×Æ®¸® ÇÁ·ÎÅäÄݺ¸´Ù ¿ì¼öÇϸç, sub-second(50 milliseconds ÀÌÇÏ) ȸº¹À» Á¦°øÇϸç
VLANs,
³×Æ®¿öÅ© ³ëµå³ª ³×Æ®¿öÅ© topology ÀÇ ¼ö¿¡ °ü°è¾øÀÌ ²ÙÁØÇÑ ´ëüÀÛµ¿À» Àü´ÞÇÑ´Ù.
EAPS
´Â ³×Æ®¿öÅ©°¡ ¸µÅ©¿À·ù·Î ºÎÅÍ °ÅÀÇ Åõ¸íÇÏ°Ô È¸º¹µÇ±â ¶§¹®¿¡
´ëºÎºÐÀÇ
»óȲ¿¡¼ VoIP ´Â ¶³¾îÁöÁö ¾ÊÀ¸¸ç µðÁöÅÐ ºñµð¿À °ø±ÞÀº µ¿°áµÇ°Å³ª pixelize È µÇÁö ¾Ê´Â´Ù.
Spanning
Tree/Rapid Spanning Tree Protocols
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ½ºÆд×Æ®¸®(802.1D), Per VLAN ½ºÆд×Æ®¸®(PVST+), Rapid ½ºÆд×Æ®¸®(802.1w)
¿Í
Layer
2 ź·Â¼ºÀ» À§ÇÑ ½ºÆд×Æ®¸®(802.1s) ÇÁ·ÎÅäÄÝÀÇ ´ÙÁß¿ä¼Ò¸¦ Á¦°øÇÑ´Ù.
Software
Enhanced Availability
Software
enhanced availability ´Â ³×Æ®¿öÅ©ÀÇ ÀÎÇÁ¶ó ÀϺΰ¡ ´Ù¿îµÇ¾úÀ»¶§ Á¶Â÷µµ À¯Àú°¡ ³×Æ®¿öÅ©¿¡ ¿¬°á»óÅ·Π³²¾ÆÀÖ°Ô
ÇØÁØ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â OSPF ,VRRP ,ESRP(ESRP supported in Layer 2 or Layer 3) ¿Í
°°Àº Áøº¸µÈ Layer 3 ÇÁ·ÎÅäÄÝÀ» ÀÌ¿ëÇÏ¿©
¾÷¸µÅ©
¿¬°á»óÅ¿¡¼ ²ÙÁØÈ÷ »óÅÂÁ¡°ËÀ» ÇÑ´Ù.
Equal
Cost Multipath
Equal
Cost Multipath ´Â ÃæºÐÇÑ ´ëüÀÛµ¿À» Áö¿øÇÏ´Â µ¿¾È¿¡ ¾÷¸µÅ©¸¦ ¼öÇà°ú ºñ¿ëÀý°¨À» À§ÇÑ ·Îµå¹ë·±½º°¡ µÇµµ·Ï ÇÑ´Ù.
¾÷¸µÅ©
¿À·ù½Ã¿¡, Æ®·¡ÇÈÀº ÀÚµ¿À¸·Î ³²ÀÌÀÖ´Â ¾÷¸µÅ©·Î ÀüȯµÇ¸ç ¿¬°á»óÅ´ À¯ÁöµÈ´Ù.
Link
Aggregation (802.3ad)
Cross
module link aggregation Àº ´ÜÀÏÁö¿ª ¿¬°á¿¡¼ 8°³ ¸µÅ©±îÁö, Áö¿ª¿¬°á¸¶´Ù ÃæºÐÇÑ ´ë¿ªÆøÀÎ 80 Gbps±îÁö
trunking À» °¡´ÉÇÏ°ÔÇÑ´Ù.
High-Performance
Connectivity
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ³×Æ®¿öÅ© ÇÏ´Ü ÀåºñÁõ°¡(IP telephones, ¹«¼±AP µî) °°Àº ³×Æ®¿öÅ· °æÇâÀ» ¹Ý¿µÇϱâ À§ÇÑ
°í¼öÇà,
ºñ¿ëÀý°¨ ¿¬°á¼ºÀ» Àü´ÞÇÑ´Ù. ÀÌ·¯ÇÑ
³×Æ®¿öÅ· °æÇâÀº µ¥½ºÅ©Å¾°ú »óÈ£¿¬°á ÅäÆú·ÎÁö·Î½á 10±â°¡ºñÆ® ÀÌ´õ³Ý ÀÌ¿ëÀ» À§ÇØ
±â°¡ºñÆ®
ÀÌ´õ³ÝÀ» À§ÇÑ ¿ä±¸»çÇ×À» ÃæÁ·ÇÑ´Ù.
Voice
and Wireless Connectivity
Voice
Grade Connections
Granular
QoS, low latency(³·Àº ´ë±â½Ã°£), low jitter(³·Àºº¯µ¿)´Â voice quality ¿¬°áÀ» °¡´ÉÇÏ°ÔÇÑ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Æ÷Æ®¸¶´Ù 8°³ÀÇ queue ¿Í ¿ì¼±¼øÀÇ ¼³Á¤°ú ³ôÀº ¿ì¼±¼øÀÇ traffic¢âpolicing À̳ª ÀԷºκÐ
Á¦ÇÑ,
802.1q
tagging °ú DiffServ marking, ¿øÈ°ÇÑ Àü¼ÛÀ» ´Ù·ê¼ö ÀÖ´Â QoS ¸¦ Áö¿øÇÑ´Ù.
High-Density
PoE
PoE
´Â BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡°¡ ´Ù¼ö IPÅÚ·¹Æ÷´Ï¿Í ¹«¼± AP ¹èÄ¡¸¦ Áö¿øÇÏ°ÔÇÑ´Ù.
BlackDiamond
8810 Àº ´ÜÀÏ 14RU »þ½Ã 3Æ÷Æ®¿¡¼ 333 Ŭ·¡½º¸¦ Áö¿øÇÒ¼ö Àְųª Ŭ·¡½º 1 ȤÀº 2 power ·Î ´ÜÀÏ »þ½Ã¿¡¼ 432
PoE port ·Î ÃÖ´ë
°ø±ÞÀÌ
°¡´ÉÇÏ´Ù. Class 1, 2 ȤÀº 3 Àåºñµé·Î ¸ðµÎ ÀûÀçµÈ
BlackDiamond 8800 ½ºÀ§Ä¡¿¡ µ¿·ÂÀ» °ø±ÞÇϱâ À§ÇØ ¿ÜºÎ power tray °¡ ÇÊ¿äÄ¡¾Ê´Ù.
Link
Layer Discovery Protocol Support
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ±â¾÷³×Æ®¿öÅ©ÀÇ ¹®Á¦ÇØ°áÀ» °£´ÜÈ÷ ÇϱâÀ§ÇØ Link Layer Discovery Protocol (LLDP)
¸¦ ÅëÇÕÇϸç
Á¤È®ÇÑ
³×Æ®¿öÅ© ÅäÆú·ÎÁö ¹ß°ß°ú À¯ÁöÇϱâÀ§ÇØ ³×Æ®¿öÅ© °ü¸®ÅøÀÇ ´É·ÂÀ» Çâ»ó½ÃŲ´Ù.
°ü¸®¿Í
Á¢¼Ó¼ºÀ» ±Ø´ë·Î °£·«È ÇÔ¿¡ ÀÇÇؼ ÁýÇÕ³×Æ®¿öÅ©ÀÇ º¹À⼺°ú ºñ¿ëÀ» ÁÙ¿©ÁØ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ±â¾÷µéÀÌ non-disruptive Plug-and-Play·Î »õ·Î¿î Á¢¼ÓÀåºñ¸¦ Ãß°¡ÇÒ¼ö ÀÖµµ·Ï ÇÏ¿©
ÁýÇÕ ¾îÇø®ÄÉÀ̼ÇÀÇ
±¹¸éÀ»
¸¶·ÃÇß´Ù. À½¼º°ú ¹«¼± ¼ºñ½º´Â Ä¿´Ù¶õ ³×Æ®¿öÅ© ¾÷±×·¹ÀÌµå ¾øÀÌ
½±°Ô ÀÌÇàµÉ¼öÀÖ´Ù.
High-Density,
Line-Rate Connectivity
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 1,200 non-blocking ±â°¡ºñÆ® Æ÷Æ®¸¦ Áö¿øÇϰųª °ÅÀÇ ¹é°³ÀÇ non-blocking 10
±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®¸¦ ´ÜÀÏ
seven
foot rack ¿¡¼ Áö¿øÇϸç, cluster(¹«¸®) ¸¦ À§ÇÑ ¸Å¿ì ºñ¿ëÀý°¨ÀûÀÎ ¿¬°á¿É¼ÇÀ» Àü´ÞÇÑ´Ù.
Jumbo
Frame Support
jumbo
frame À» Áö¿øÇÏ´Â °ÍÀº ³×Æ®¿öÅ© ¼öÇàÀ» ÃÖÀûÈ ÇϱâÀ§ÇÑ cluster computing ¾îÇø®ÄÉÀ̼ÇÀ» Çã¿ëÇÑ´Ù.
IPv6
Packet Forwarding Support
IPv6
´Â »õ·Î¿î IPÁÖ¼Ò¸¦ trillion(100°æ) ¸¸ÅÀ̳ª »ç¿ë°¡´ÉÇÏ°Ô ¸¸µé¸ç, ´õ ³ªÀº ÁÖ¼ÒÇÒ´ç, ÁÖ¼ÒÁýÇÕ ±×¸®°í ±²ÀåÈ÷ ¶Ù¾î³
end-to-end ¿¬°á¼º°ú
¼ºñ½º¸¦
Á¦°øÇϴ Ư¡µéÀ» Çã¿ëÇÑ´Ù. BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ÇöÀçÀÇ IPv6 ¸¦ Áö¿øÇÏ¸ç ±â¾÷ÀÌ IPv6 Æ®·¡ÇÈÀ» ´Ù·ê¼öÀÖ°Ô ÇØÁÖ¸ç,
ÀÌÆ®·¡ÇÈÀº
¾î¶² ³×Æ®¿öÅ©¿¡µµ µé¾î°¥¼öÀÖ´Ù.
Large
Switching Capacity
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 800 Gbps ½ºÀ§Ä¡ ±¤´ë¿ªÆøÀ» Àü´ÞÇϸç 570 Mpps ÀÌ»óÀÇ Layer 2- Layer
3 Çϵå¿þ¾î Àü¼Û·üÀ» Àü´ÞÇÑ´Ù.
- 800 Gbps switch fabric bandwidth
- 48 Gbps per slot capacity
- Over 570 Mpps Layer 2/Layer 3 hardware
forwarding rate
- Local switching on every I/O module
Module Name |
G48Te |
G48Pe |
G48Ta |
G48Xa |
G48T |
G48P |
G48X |
MSM-G8X1 |
10G4X |
10/100/1000BASE-T ports |
48 |
48 PoE |
48 |
/ |
48 |
48 PoE |
/ |
/ |
/ |
1000X mini-GBIC ports |
/ |
/ |
/ |
48 |
/ |
/ |
24 |
8 |
|
10GBASE-X XENPAK ports |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
/ |
4 |
Backplane capacity (Gbps) 2*MSM/1*MSM |
24/12 |
24/12 |
48/24 |
48/24 |
48/24 |
48/24 |
48/24 |
12 |
48/24 |
Load Sharing Groups |
128 |
128 |
128 |
128 |
128 |
128 |
128 |
128 |
32 |
Jumbo Frame per port2 |
Per Port |
Per Port |
Per Port |
Per Port |
Per System |
Per System |
Per System |
Per System |
Per System |
Layer 2 MAC FDB |
8K per module |
8K per module |
16K per module |
16K per module |
16K per module |
16K per module |
16K per module |
16K per module |
16K per module |
IPv4 LPM entries |
512 |
512 |
12K |
12K |
8K |
8K |
8K |
8K |
8K |
IPv4 Host entries |
2K |
2K |
8K |
8K |
8K |
8K |
8K |
8K |
8K |
IPv6 forwarding3 |
Hardware |
Hardware |
Hardware |
Hardware |
Software |
Software |
Software |
Software |
Software |
1 |
The 8-port gigabit Ethernet ports on
MSM-G8X |
2 |
Future Release |
3 |
Future Release for harware-based IPv6 routing |
Flexible
Connectivity
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ƯÁ¤ ¾îÇø®ÄÉÀ̼ǿ¡ ÃÖÀûÈµÈ °íź·Â¼º ¿¬°á¿É¼ÇÀ» Á¦°øÇÑ´Ù.
"e"
series Gigabit ÀÌ´õ³Ý ¸ðµâÀº PoE ¿©ºÎ »ó°ü¾øÀÌ ±â°¡ºñÆ® edge(ÇÏ´Ü) Á¢¼Ó¼ºÀ» Á¦°øÇϱâ À§ÇØ ¼³°èµÇ¾úÀ¸¸ç,
"a"
series Gigabit ÀÌ´õ³Ý ¸ðµâÀº ±â°¡ºñÆ® ÁýÇÕÀ̳ª ¼¹ö½ºÀ§Äª ȯ°æ¿¡¼ ³ôÀº scalable(ÃøÁ¤°¡´ÉÇÑ) ¿¬°á¼ºÀ» Á¦°øÇϱâÀ§ÇØ
¼³°èµÇ¾ú´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡¸¦ ÀÌ¿ëÇÑ ´Ù¼ö¿¬°á ¿É¼ÇÀ» Figure 2 ¿¡ ¿ä¾àÇÏ¿´´Ù.
Comprehensive
Security Using Defense-in-Depth
º¸¾È
³×Æ®¿öÅ©¸¦ ÀÌÇàÇÑ´Ù´Â °ÍÀº Áß¾Ó»Ó¸¸ ¾Æ´Ï¶ó ³×Æ®¿öÅ© ¿Ü°¢¿¡¼µµ ¹æ¾î¸¦ Á¦°øÇϴ°ÍÀ» ÀǹÌÇÑ´Ù.
Extreme
Networks Sentriant¢â Á¦Ç°±º°ú ÇÔ²² ÀÛµ¿ÇÔÀ¸·Î½á, BlackDiamond 8800 ½ºÀ§Ä¡´Â ¾Ë·ÁÁö°Å³ª ±×·¸Áö ¾ÊÀº
À§ÇùÀ¸·ÎºÎÅÍ
³×Æ®¿öÅ©¸¦
º¸È£Çϴµ¥ ÀÖ¾î¼ defense-in-depth
strategy ¸¦ ÀÌ¿ëÇÑ´Ù.
Directory-Integrated
Link Security
Intelligent
Network Access
Áö´ÉÀûÀÎ
³×Æ®¿öÅ© Á¢¼ÓÀº À¯Àú½ÂÀΰú ÀÌ¿ëÁ¤Ã¥À» °ÈÇÑ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 802.1x agent-based Á¢±ÙÀ» Á¦°øÇÔÀ¸·Î½á ±¤¹üÀ§ÇÑ ³×Æ®¿öÅ© ·Î±ä ¿É¼Ç, °Ô½ºÆ®¸¦ À§ÇÑ À¥±â¹Ý
·Î±ä´É·Â,
ÀåÄ¡¸¦
À§ÇÑ MAC ±â¹Ý ÀÎÁõ¸ðµ¨À» Áö¿øÇÑ´Ù.
ÀÌ·¯ÇÑ
³×Æ®¿öÅ© ·Î±ä ¸ðµå·Î½á, ½ÂÀÎµÈ À¯Àú¿Í Àåºñµé¸¸ ³×Æ®¿öÅ© Á¢¼ÓÀÌ °¡´ÉÇϸç Àû´çÇÑ VLAN À» ÇÒ´ç¹Þ´Â´Ù.
Multiple
Supplicant Support
ºÐÇÒµÈ
Æ÷Æ®´Â ³×Æ®¿öÅ©¿¡¼ ÀáÀçÀûÀ¸·Î Ãë¾àÇÔÀ» ³ªÅ¸³½´Ù.
½ºÀ§Ä¡¿¡¼
Multiple Supplicant ´É·ÂÀº µ¶Æ¯ÇÑ ½ÂÀÎÀ» Çã¿ëÇÏ¸ç ºÐÇÒµÈ Æ÷Æ®¿¡¼ °¢±â À¯Àú¸¦ À§ÇÑ Àû´çÇÑ Á¤Ã¥°ú VLANÀ»
Àû¿ëÇÑ´Ù.
Multiple
supplicant ´Â º¸¾È IP ÅÚ·¹Æ÷´Ï¿Í ¹«¼±Á¢¼ÓÀ» Áö¿øÇÑ´Ù. ÁýÇÕ³×Æ®¿öÅ© ¼³°è´Â Á¾Á¾ ºÐÇÒµÈ Æ÷Æ®ÀÇ ÀÌ¿ëÀ» ¼ö¹ÝÇÑ´Ù.
PC
plugging into an IP telephone
´Ù¼öÀ¯ÀúµéÀº
¹«¼±AP ȤÀº Layer 2 ½ºÀ§Ä¡/Çãºê¸¦ ÅëÇؼ Á¢¼ÓµÇ¹Ç·Î °°Àº ¹°¸®Àû PoE Æ÷Æ®¸¦ °øÀ¯ÇÑ´Ù.
Host
Integrity Checking
È£½ºÆ®
¹«°á¼º °Ë»ç´Â °¨¿°µÇ°Å³ª ¸í·É¿¡ ºÒÀÀÇÏ´Â ÀåºñµéÀ» ³×Æ®¿öÅ©·ÎºÎÅÍ °Ý¸®½ÃŲ´Ù. BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Trusted Computing
Group ÀÇ ¸ðµ¨À» ±â¹ÝÀ¸·ÎÇÑ È£½ºÆ® ¹«°á¼ºÀ̳ª endpoint(¸ñÀûÁö)
¹«°á¼º ¼Ö·ç¼ÇÀ» Áö¿øÇÑ´Ù.
Threat
Detection and Response
sFlow®
sFlow
´Â ¸ðµçÀåÄ¡¿¡¼ µ¿½Ã¿¡ ¾îÇø®ÄÉÀÌ¼Ç level Æ®·¡ÇÈ È帧À» sample ÇϱâÀ§ÇÑ ´É·ÂÀ» Á¦°øÇÏ´Â sampling ±â¼úÀÌ´Ù.
"e"
½Ã¸®Áî¿Í "a" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº Çϵå¿þ¾î ¿¡¼ sFlow sampling À» Áö¿øÇÑ´Ù.
Port
Mirroring
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â many-to-one °ú cross module port mirroring À» Áö¿øÇÑ´Ù.
ºÐ¼®À»
À§ÇÑ Ä§ÀÔÂ÷´Ü Àåºñ¿Í °°Àº ¿ÜºÎ³×Æ®¿öÅ© Àåºñ·Î ÇâÇÑ mirror Æ®·¡ÇÈ¿¡ ÀÌ¿ëµÉ¼ö Àְųª ³×Æ®¿öÅ© °ø°Ý¿¡ ´ëÀÀÇÒ¶§ Áø´ÜÅø·Î½á
³×Æ®¿öÅ©
°ü¸®ÀÚ¿¡ ÀÇÇØ È°¿ëµÈ´Ù.
Line-Rate
Access Control Lists (ACLs)
ACLs
´Â ³×Æ®¿öÅ© ÀÚ¿ø È°¿ëÀ» Á¦¾îÇÏ¸ç ³×Æ®¿öÅ© º¸¾È°ú ¹æ¾î¸¦ À§ÇÑ °¡Àå °·ÂÇÑ ÅøÁßÀÇ ÇϳªÀÌ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â MAC address or IP source/destination address or TCP/UDP
port number ¿Í °°Àº Layer 2, 3 ³ª
4-header
information À» ±â¹ÝÇÑ Çϵå¿þ¾î ±â¹Ý ACLs ¸¦ Áö¿øÇÑ´Ù.
"e"
½Ã¸®Áî¿Í "a" ½Ã¸®Áî ¸ðµâÀº ±â°¡ºñÆ® ÀÌ´õ³ÝÀÇ 24-port block ¸¶´Ù Áß¾ÓÁýÁßÇü ACL ¸®¼Ò½º¸¦ Á¦°øÇÔ¿¡
ÀÇÇؼ ¶Ù¾î³ ACL È®À强À» Á¦°øÇÑ´Ù.
Áß¾ÓÁýÁßÇü
¸®¼Ò½º´Â ´Ù¼öÆ÷Æ®¸¦ ÅëÇØ °øÀ¯µÉ¼öÀÖ´Ù. ±×·¯¹Ç·Î ´ÜÀÏ Çϵå¿þ¾î ¸®¼Ò½º´Â 24 Æ÷Æ®·Î ºÐ¹èµÉ¼öÀÖ´Ù.
"e"
½Ã¸®Áî¿Í "a" ½Ã¸®Áî ¸ðµâÀ» À§ÇÑ ACL ¿£ÁøÀº ¶ÇÇÑ 16°³ ±îÁöÀÇ µ¶Æ¯ÇÑ TCP/UDP port range
¸¦ °áÇÕÇϱâÀ§ÇÑ ´É·ÂÀ» Á¦°øÇÑ´Ù.
±×·¡¼
Á÷¼±»óÀ¸·Î TCP/UDP port °ªÀÌ setting µÉ¶§ Á¶Â÷µµ ´ÜÁö ÇϳªÀÇ ´ÜÀÏ Çϵå¿þ¾î ¸®¼Ò½º¸¸ÀÌ ¿ä±¸µÈ´Ù.
Hardened
Network Infrastructure
Denial
of Service (DoS) Protection
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â DoS °ø°ÝÀ» ÈǸ¢ÇÏ°Ô ´Ù·é´Ù. ½ºÀ§Ä¡°¡
CPU ÀÔ·Â queue ¿¡¼ ºñÁ¤»ó ÀûÀ¸·Î ¸¹Àº¼öÀÇ ÆÐŶÀ» ŽÁöÇÑ´Ù¸é,
cpu
µµÀÛÀ¸·Î ºÎÅÍ À̵éÆÐŶÀ» ÀÚµ¿À¸·Î ÁßÁö½ÃÅ°´Â ACLs¸¦ ¼ÒÁýÇÒ°ÍÀÌ´Ù. ¾ó¸¶ÈÄ¿¡,
ACLs´Â Á¦°ÅµÈ´Ù. ¸¸¾à °ø°ÝÀÌ °è¼ÓµÈ´Ù¸é
´Ù½Ã¼³Ä¡µÉ °ÍÀÌ´Ù.
Module Name |
G48Te |
G48Pe |
G48Ta |
G48Xa |
G48T |
G48P |
G24X |
MSM-G8X |
10G4X |
ACL hardware resources1 |
Centralized per 24-port block |
Centralized per 24-port block |
Centralized per 24-port block |
Centralized per 24-port block |
Per Port Basis |
Per Port Basis |
Per Port Basis |
Per Port Basis |
Per Port Basis |
Policy based routing2 |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
No |
sFlow sampling |
Hardware |
Hardware |
Hardware |
Hardware |
Software |
Software |
Software |
Software |
Software |
1 |
For more detailed description on
Access Control List feature, please refer to the ExtremeXOS 11.5 Concept
Guide (http://www.extremenetworks.com/services/documentation/swuserguides.asp) |
2 |
Policy-based routing should be
supported on the module where packet ingresses on its port. Egress port does not
require policy-based routing support on the module. |
Policy
Based Routing
Policy-based
routing Àº ³×Æ®¿öÅ©ÀÇ Æ®·¡ÇÈ È帧À» customize(»ç¿ëÀÚ ÁöÁ¤) ÇϱâÀ§ÇØ ³×Æ®¿öÅ© °ü¸®ÀÚ¸¦ À§ÇÑ À¶Å뼺ÀÖ´Â mechanism
À» Á¦°øÇÑ´Ù.
½ºÀ§Ä¡¿¡¼
ȯ°æ¼³Á¤µÈ ACLs ´Â ±×µéÀÇ º¸Åë °æ·Î·ÎºÎÅÍ ´Ù¸¥ ¹°¸®Àû ½ºÀ§Ä¡ Æ÷Æ®·Î ÀüȯÇÒ¼öÀÖ´Ù.
ÆÐŶÀº
QoS, VLAN, IP ÁÖ¼Ò, ÇÁ·ÎÅäÄÝ, Æ÷Æ®¹øÈ£³ª ´Ù¸¥Ç¥Áصé°ú °°Àº ACLs match condition ¿¡ ÀÏÄ¡Çϴ°ÍÀÌ
¼±ÅõȴÙ.
"e"
½Ã¸®Áî¿Í "a" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº policy-based routing ´É·ÂÀ» Á¦°øÇÑ´Ù.
ASIC-based
Longest Prefix Match (LPM)
LPM
routing Àº »õ·Î¿î È帧À» ¹è¿ì´Â control plane software ÀÇ Çʿ伺À» °æ°¨½ÃÅ°¸ç ³×Æ®¿öÅ©´Â DoS °ø°Ý¿¡
ź·ÂÀûÀ¸·Î µÈ´Ù.
Secure
Management
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡¿¡ ÀÇÇØ Áö¿øµÇ´Â SSH2 ,SCP ,SNMPv3 ¿Í°°Àº ÇÁ·ÎÅäÄÝÀÇ ÀÌ¿ëÀº °ü¸®¿î¿µ°ú man-in-the-middle
attack ÀÇ
¿ä°ÝÀ»
¹æÁöÇÑ´Ù,
MD5
Authentication of Routing Protocols
Routing
ÇÁ·ÎÅäÄÝÀÇ MD5 ½ÂÀÎÀº °ø°ÝÀÚµéÀÌ À¯È¿¸Þ½ÃÁö º¯°æ°ú routing session À» °ø°ÝÇϴ°ÍÀ» ¸øÇÏ°ÔÇÑ´Ù.
Target
Applications
Application
and Recommended Connectivity Options
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´Ù¾çÇÑ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ÃÖ»óÀ¸·Î ¾Ë¸Â´Â ³×Æ®¿öÅ· ¼Ö·ç¼ÇÀ» Á¦°øÇÏ´Â ´Ù¾çÇÑ ¿¬°á¿É¼ÇÀ» °¡Áö°íÀÖ´Ù.
"e"
½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº gigabit PoE edge, µ¥½ºÅ©Å¾ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ±â°¡ºñÆ®¿Í °°Àº edge ¾îÇø®ÄÉÀ̼ǿ¡
ÃÖ»óÀÌ´Ù.
"a"
½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº(G48Ta and G48Xa) HPCC ¿Í ÁýÇÕ ¾îÇø®ÄÉÀ̼ǰú °°Àº ¾îÇø®ÄÉÀ̼ǿ¡¼ ¿ä±¸¸¦ ¸¸Á·½ÃÅ°´Â
°í È®À强À»
Á¦°øÇÑ´Ù.
¾Æ·¡ ÃÆ®´Â BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡°¡
Á¦°øÇÏ´Â ³×°³ÀÇ ÁÖ¿ä ¾îÇø®ÄÉÀ̼ǿ¡ ÀÇÇÑ ±ÇÀå¸ðÆ« ŸÀÔÀ» ¼³¸íÇÑ´Ù.
High-Density
PoE Edge Switch for Integrated Wired, Wireless and IP Telephony
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´ÙÀ½°ú °°Àº ³×Æ®¿öÅ· °æÇâ¿¡ ÀÌÇØ ÁÖ¾îÁø °í¼º´É°ú ºñ¿ëÀý°¨Àû ¿¬°á¼ºÀ» Àü´ÞÇÑ´Ù.
Áõ°¡ÇÏ´Â
IP telephone, ¹«¼±AP, ³×Æ®¿öÅ© ÇÏ´ÜÀÇ ´Ù¸¥Àåºñµé, µ¥½ºÅ©Å¾À» ÇâÇÑ ±â±âºñÆ® ÀÌ´õ³Ý Á¢¼Ó, »óÈ£¿¬°á ±â¼ú·Î½á
±â°¡ºñÆ®¿Í
10±â°¡ºñÆ® ÀÌ´õ³ÝÀÇ ÀÌ¿ë
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´ÜÀÏÅëÇÕ Á¢¼Ó·¹À̾î·Î ÅëÇյDZâ À§ÇØ ÀüÅëÀûÀÎ edge layer ¿Í ³×Æ®¿öÅ©ÀÇ ÁýÇÕ layer ¸¦ Çã¿ëÇÑ´Ù.
edge
¾îÇø®ÄÉÀ̼ǿ¡¼, G48Te ¿Í G48Pe ¸ðµâÀº BlackDiamond 8800 ¸ðµâÀÇ ÃÖ»óÀÇ edge Á¢¼Ó¼ºÀ» Á¦°øÇÑ´Ù.
High
Performance Cluster Computing
HPCC
´Â Ä¿´Ù¶õ °è»ê»óÀÇ ¹®Á¦¸¦ ÇØ°áÇϱâ À§ÇØ »óÈ£º¸¿ÏÀûÀ¸·Î ÀÛµ¿ÇÏ´Â ¼ö¹é ȤÀº ¼öõ°³ÀÇ ¼¹ö·Î ±¸¼ºµÇ¾îÀÖ´Ù.
»ó´ëÀûÀ¸·Î
Àú·ÅÇÏ¸ç ¼ÒÇüÈµÈ 1RU ¼¹öÀÇ ÀÌ¿ëÀ¸·Î, °Å´ëÇÑ ¾çÀÇ Ã³¸®ÆÄ¿ö´Â »ó´ëÀûÀ¸·Î ÀÛÀº footprint(¹üÀ§) ·Î µé¾î°¡¼ ºñ¿ëÀý°¨ÀûÀ¸·Î
µÉ¼öÀÖ´Ù.
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â »óÈ£¿¬°á ±â¼ú·Î½á ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» ÀÌ¿ëÇÑ HPCC ¿¡ ¿ä±¸µÇ´Â °í¼öÇà°ú ºñ¿ëÀý°¨Àû ¿¬°á¼ºÀ»
À§ÇÑ
Çʿ伺À» º¸¿©ÁØ´Ù. HPCC
¾îÇø®ÄÉÀ̼ǿ¡¼, G48Ta ¸ðµâÀº ±â°¡ºñÆ® ÀÌ´õ³Ý ¼¹ö¸¦ À§ÇÑ °í¼öÇàÀ» Á¦°øÇÑ´Ù.
10G4X
¸ðµâÀº 10 ±â°¡ºñÆ® ÀÌ´õ³Ý ¿¬°áÀ» À§ÇØ »ç¿ëµÉ¼öÀÖ´Ù.
Single
Switch Medium-Sized Network
BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Áß°ß±â¾÷¿¡°Ô ³×Æ®¿öÅ© ¿ä±¸¸¦ ¿Ïº®È÷ ¸¸Á·½ÃÄÑÁÖ´Â ÀÌ»óÀûÀÎ ´ÜÀÏ ½ºÀ§Ä¡ ¼Ö·ç¼ÇÀ» Á¦°øÇÑ´Ù.
ÀüÇüÀûÀÎ
multi-switch ³×Æ®¿öÅ©´Â IP ÅÚ·¹Æ÷´Ï, ¼ºñ½º¿Í °³¼±µÈ º¸¾ÈÀ» À§ÇÑ ÃÊ°í¼Ó ¼öÇàÀ» À§ÇÑ °í¹Ðµµ PoE ¸¦ Àü´ÞÇÏ´Â
´ÜÀÏ °íÀ̿뼺
½ºÀ§Ä¡¿Í
¿¬µ¿µÉ¼öÀÖ´Ù. G48Te ¿Í G48Pe ¸ðµâÀº ¾îÇø®ÄÉÀ̼ǿ¡¼
´Ù¾çÇÑ ÇÏ´ÜÀåºñµéÀ» À§ÇÑ ¿¬°á¼ºÀ» Á¦°øÇÑ´Ù.
Traditional
Aggregation Layer
Extreme
³×Æ®¿öÅ©´Â two-tier ³×Æ®¿öÅ©°¡ ´õ°£ÆíÇÑ Á¢±ÙÀ̶ó°í ¹Ï´Â ¹Ý¸é¿¡, building or campus or the wiring
plant ÀÇ ¼³°è´Â °¡²û
ÁýÇÕ·¹À̾
¿ä±¸ÇÑ´Ù. ÀÌ ·¹À̾î´Â ÀüÇüÀûÀ¸·Î ÇϴܽºÀ§Ä¡·Î ºÎÅÍ ±â°¡ºñÆ®³ª
10±â°¡ºñÆ® ¾÷¸µÅ©¸¦ ¸ðÀ¸¸ç, ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ®
ÀÌ´õ³Ý
¾÷¸µÅ©¸¦ ÅëÇÏ¿© Áß¾Ó(¹éº»)À¸·Î ¿¬°áÇÑ´Ù. BlackDiamond
8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °í¹Ðµµ ±â±âºñÆ®¿Í ÁýÇÕ·¹À̾ ¿ä±¸µÇ´Â
10±â°¡ºñÆ®
ÀÌ´õ³ÝÀ» Á¦°øÇÑ´Ù. G48Ta ¿Í G48Xa ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº °í¼öÇà°ú È®À强À» Á¦°øÇÑ´Ù. 10G4X ¸ðµâÀº 10±â°¡ºñÆ®
ÀÌ´õ³Ý
¿¬°á¼ºÀ» À§ÇØ ÀÌ¿ëµÉ¼öÀÖ´Ù.
TECHNICAL SPECIFICATIONS |
|
General Routing and
Switching |
| RFC 1812
Requirements for IP Version 4 Routers |
|
|
RFC 1519 CIDR |
|
| RFC 1256 IPv4 ICMP
Router Discovery (IRDP) |
|
|
RFC 1122 Host Requirements |
|
| RFC 768 UDP |
|
|
RFC 791 IP |
|
|
RFC 792 ICMP |
|
|
RFC 793 TCP
|
|
|
RFC 826 ARP |
|
|
RFC 894 IP over Ethernet |
|
| RFC 1027 Proxy ARP |
|
| RFC 1866 HTML - Used
for web-based Network Login |
|
| RFC 2068 HTTP server
- Used for web-based Network Login |
|
| RFC 2338 VRRP |
|
|
RFC 3619 Ethernet
Automatic Protection Switching (EAPS) and EAPSv2 |
|
| IEEE 802.1D - 1998 Spanning Tree Protocol
(STP) |
|
| IEEE 802.1w - 2001 Rapid Reconfiguration
for STP, RSTP |
|
| IEEE 802.1s - 2004 Multiple Instances of
STP, MSTP |
|
| Extreme Multiple Instances of Spanning Tree
Protocol (EMISTP) |
|
|
PVST+, Per VLAN STP
(802.1Q interoperable) |
|
| Extreme Standby Router
Protocol (ESRP) |
|
| IEEE 802.1Q - 1998
Virtual Bridged Local Area Networks |
|
| IEEE 802.1AB - Link
Layer Discovery Protocol (LLDP) |
|
| LLDP Media Endpoint
Discovery (LLDP-MED) ANSI/TIA-1057, draft 08 |
|
| Extreme Discovery
Protocol (EDP) |
|
| Static Unicast Routes |
|
| Extreme Loop Recovery
Protocol (ELRP) |
|
|
Software Redundant
Ports |
|
VLANs, vMANs |
|
|
IEEE 802.1Q VLAN Tagging |
|
|
IEEE 802.3ad Static load sharing configuration
and LACP based dynamic configuration |
|
|
IEEE 802.1v: VLAN classification by Protocol
and Port |
|
|
Port-based VLANs |
|
|
Protocol-based VLANs |
|
| Multiple STP domains per VLAN |
|
| Virtual MANs (vMANs) |
|
Quality of Service
and Policies |
|
|
IEEE 802.1D -1998 (802.1p) Packet Priority |
|
| RFC 2474 DiffServ
Precedence, including 8 queues/port |
|
| RFC 2598 DiffServ
Expedited Forwarding (EF) |
|
|
RFC 2597 DiffServ Assured Forwarding (AF) |
|
|
RFC 2475 DiffServ
Core and Edge Router Functions |
|
RIP |
|
|
RFC 1058 RIP v1 |
|
| RFC 2453 RIP v2 |
|
OSPF |
|
| RFC 2328 OSPF v2 (including
MD5 authentication) |
|
| RFC 1587 OSPF NSSA Option |
|
| RFC 1765 OSPF Database
Overflow |
|
| RFC 2370 OSPF Opaque
LSA Option |
|
| RFC 3623 OSPF Graceful
Restart |
|
BGP4 |
|
|
RFC 1771 Border Gateway
Protocol 4 |
|
|
RFC 1965 Autonomous
System Confederations for BGP |
|
| RFC 2796 BGP Route
Reflection (supersedes RFC 1966) |
|
|
RFC 1997 BGP Communities
Attribute |
|
| RFC 2385 TCP MD5 Authentication
for BGPv4 |
|
| "draft-ietf-idr-restart-10.txt
(Graceful Restart Mechanism for BGP)" |
|
| RFC 2439 BGP Route Flap Damping
|
|
| RFC 2842 Capabilities
Advertisement with BGP-4 |
|
|
RFC 2918 Route Refresh
Capability for BGP-4 |
|
IPv4 Multicast |
|
|
RFC 1112 IGMP v1 |
|
|
RFC 2236 IGMP v2 |
|
|
RFC 3376 IGMP v3 |
|
|
IGMP v1/v2/v3 Snooping with Configurable
Router Registration Forwarding |
|
|
IGMP Filters |
|
|
Static IGMP Membership |
|
|
Multicast VLAN Registration |
|
|
RFC 2362 PIM-SM |
|
| PIM-DM Draft IETF PIM Dense Mode
draft-ietfidmr-pim-dm-05.txt, draft-ietf-pim-dm-new-v2-04.txt
|
|
| RFC 3569, draft-ietf-ssm-arch-06.txt
PIM-SSM PIM Source Specific Multicast |
|
Management and Traffic
Analysis |
|
|
RFC 2030 SNTP, Simple Network Time Protocol
v4 |
|
|
RFC 854 Telnet client and server |
|
|
RFC 783 TFTP Protocol (revision 2) |
|
|
RFC 951, 1542 BootP |
|
|
RFC 2131 BOOTP/DHCP relay agent and DHCP
server |
|
|
RFC 1591 DNS (client operation) |
|
|
RFC 1155 Structure of Mgmt Information (SMIv1) |
|
|
RFC 1157 SNMPv1 |
|
|
RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like
MIB & TRAPs |
|
|
RFC 1573 Evolution of Interface |
|
|
RFC 1650 Ethernet-Like MIB (update of RFC
1213 for SNMPv2) |
|
|
|
|
RFC 1901 - 1908 SNMP v2c, SMIv2 and Revised
MIB-II |
|
|
RFC 2570 - 2575 SNMPv3, user based security,
encryption and authentication |
|
|
RFC 2576 Coexistence between SNMP Version
1, Version 2 and Version 3 |
|
|
RFC 1757 RMON 4 groups: Stats, History,
Alarms and Events |
|
|
|
|
RFC 2021 RMON2 (probe configuration) |
|
|
RFC 2668 802.3 MAU MIB |
|
|
RFC 1643 Ethernet MIB |
|
|
RFC 1493 Bridge MIB |
|
|
RFC 1354 IPv4 Forwarding Table MIB |
|
|
RFC 2737 Entity MIB v2 |
|
|
RFC 2233 Interface MIB |
|
|
RFC 1354 IP Forwarding Table MIB |
|
| RFC 2737 Entity MIB, Version 2 |
|
| RFC 2233 Interface MIB |
|
| RFC 3621 PoE-MIB |
|
| RFC 1354 IP Forwarding Table MIB |
|
| RFC 1724 RIPv2 MIB |
|
| RFC 1850 OSPFv2 MIB |
|
| RFC 1657 BGP-4 MIB |
|
|
Draft-ietf-idr-bgp4-mibv2-02 .txt-Enhanced BGP-4MIB
|
|
| draft-ietf-pim-mib-v2-o1.txt |
|
| RFC 2787 VRRP MIB |
|
| RFC 2925 Ping/Traceroute/NSLOOKUP MIB |
|
|
Draft-ietf-bridge-rstpmib-03 .txt - Definitions
of Managed Objects for Bridges with Rapid Spanning Tree
Protocol |
|
|
Secure Shell (SSH-2) client and server |
|
|
Secure Copy (SCP-2) client and server |
|
|
Secure FTP (SFTP) server |
|
|
sFlow version 5 |
|
|
Configuration logging |
|
|
Multiple Images, Multiple Configs |
|
|
BSD System Logging Protocol (SYSLOG), with
Multiple Syslog Servers |
|
|
999 Local Messages (criticals stored across
reboots) |
|
| Extreme Networks vendor MIBs (includes FDB,
PoE, CPU, Memory MIBs) http://www.extremenetworks. com/services/documentation
|
|
Security |
|
|
Routing protocol MD5 authentication (see
above) |
|
|
Secure Shell (SSH-2), Secure Copy (SCP-2)
and SFTP client/server with encryption/authentication
(requires export controlled encryption module) |
|
|
SNMPv3 user based security, with encryption/authentication
(see above) |
|
|
RFC 1492 TACACS+ |
|
|
RFC 2138 RADIUS Authentication |
|
|
RFC 2139 RADIUS Accounting |
|
|
RADIUS Per-command Authentication |
|
|
Access Profiles on All Routing Protocols |
|
|
Access Policies for Telnet/SSH-2/SCP-2 |
|
|
Network Login - 802.1x, web and MAC-based
mechanisms |
|
|
IEEE 802.1x - 2001 Port-Based Network Access
Control for Network Login |
|
|
Multiple supplicants for Network Login (all
modes) |
|
|
Fallback to local database (MAC and Web-based
methods) |
|
|
Guest VLAN for 802.1x |
|
|
SSL/TLS transport - used for for web-based
Network Login, (requires export controlled encryption
module) |
|
|
MAC Address Security - Lockdown and Limit |
|
| RFC 3046
IP Address Security - DHCP Option 82 |
| IP Address
Security - Gratuitous ARP Protection |
| Layer 2/3/4
ACLs |
Denial of Service Protection
|
|
| RFC 2267 Network Ingress Filtering |
|
| RPF (Unicast Reverse Path Forwarding) Control
via ACLs |
|
| Wire-speed ACLs |
|
| Rate Limiting/Shaping by ACLs |
|
| IP Broadcast Forwarding Control |
|
| ICMP and IP-Option Response Control |
|
| SYN attack protection |
|
|
CPU DoS Protection with traffic rate limiting
to management CPU |
|
Robust against common
Network Attacks |
|
| CERT (http://www.cert.org) |
|
| CA-2003-04: "SQL Slammer" |
|
| CA-2002-36: "SSHredder" |
|
| CA-2002-03: SNMP vulnerabilities |
|
|
CA-98-13: tcp-denial-of-service |
|
|
CA-98.01: smurf |
|
|
CA-97.28: Teardrop_Land -Teardrop and "LAND"
attack |
|
|
CA-96.26: ping |
|
|
CA-96.21: tcp_syn_flooding |
|
|
CA-96.01: UDP_service_denial |
|
|
CA-95.01: IP_Spoofing_Attacks_and_ Hijacked_Terminal_Connections |
|
|
IP Options Attack |
|
Host Attacks
|
|
| Teardrop, boink, opentear, jolt2, newtear,
nestea, syndrop, smurf, fraggle, papasmurf, synk4, raped,
winfreeze, ping -f, ping of death, pepsi5, Latierra, Winnuke,
Simping, Sping, Ascend, Stream, Land, Octopus |
|
IPv6 |
|
| RFC 2460, Internet Protocol, Version 6 (IPv6)
Specification |
|
| RFC 2461, Neighbor Discovery for IP Version
6, (IPv6) |
|
| RFC 2462, IPv6 Stateless Address Auto configuration
- Router Requirements |
|
| RFC 2463, Internet Control Message Protocol
(ICMPv6) for the IPv6 Specification |
|
| RFC 2464, Transmission of IPv6 Packets over
Ethernet Networks |
|
| RFC 2465, IPv6 MIB, General Group and Textual
Conventions |
|
| RFC 2466, MIB for ICMPv6 |
|
|
|
|
|
|
|
|
|
|
| RFC 1981, Path MTU Discovery for IPv6, August
1996 - Router requirements |
|
| RFC 3513, Internet Protocol Version 6 (IPv6)
Addressing Architecture |
|
| RFC 3587, Global Unicast Address Format |
|
|
RFC 2710, IPv6 Multicast Listener Discovery
v1 (MLDv1) Protocol |
|
| RFC 3810, IPv6 Multicast Listener Discovery
v2 (MLDv2) Protocol |
|
| RFC 2740, OSPF for IPv6 |
|
| RFC 2080, RIPng |
|
| RFC 2893, Configured Tunnels |
|
| RFC 3056, 6to4 |
|
|
Static Unicast routes for IPv6 |
|
|
Telnet over IPv6 transport |
|
|
SSH-2 over IPv6 transport |
|
|
Ping over IPv6 transport |
|
|
Traceroute over IPv6 transport |
|
|
|
|
|
Switching Capacity |
|
|
800 Gbps total switching capacity |
|
|
4.016 Tbps total switching capacity (Including
local switching) |
|
|
570 Mpps Layer 2 HW forwarding rate |
|
|
570 Mpps Layer
3 HW forwarding rate |
|
Port Capacity |
|
BlackDiamond 8810 |
|
|
36 ports 10GBASE-X (XENPAK) (32 ports if
2 MSMs) |
|
|
432 ports 10/100/1000BASE-T (384 ports if
2 MSMs) |
|
|
440 ports 1000BASE-X SFP (Mini-GBIC) (400
ports if 2 MSMs) |
|
BlackDiamond 8806 |
|
|
20 ports 10GBASE-X (XENPAK) (16 ports if
2 MSMs) |
|
|
240 ports 10/100/1000BASE-T (192 ports if
2 MSMs) |
|
|
248 ports 1000BASE-X SFP (Mini-GBIC) (208
ports if 2 MSMs) |
|
Management Switch Module |
|
|
The management module contains both the
control path as well as the switch fabric for the BlackDiamond
8800 |
|
MSM-G8X BlackDiamond 8800 Management
Switch Module, with 8 1000BASE-X mini-GBIC ports |
|
I/O Module Options |
|
G48Te 48-port 10/100/1000BASE-T Gigabit
Ethernet module 2:1 oversubscription |
|
G48Pe 48-port 10/100/1000BASE-T Gigabit
Ethernet module with PoE 2:1 oversubscription |
|
G48T 48-port 10/100/1000BASE-T Gigabit
Ethernet module |
|
G48P 48-port 10/100/1000BASE-T Gigabit
Ethernet module with PoE |
|
G48Ta 48-port 10/100/1000BASE-T Gigabit
Ethernet module |
|
G24X 24-port 1000BASE-X Gigabit Ethernet
module, mini-GBIC modules required |
|
G48Xa 48-port 1000BASE-X Gigabit Ethernet
module, mini-GBIC modules required |
|
10G4X 4-port 10GBASE-X 10 Gigabit Ethernet
module |
|
|
XENPAK modules required |
|
|
XENPAK options include |
|
|
- SR (up to 300 m) |
|
|
- LR (up to 50 km) |
|
|
- ER (up to 40 km) |
|
|
- ZR (up to 80 km) |
|
|
- LX4 (300m MMF, 10 km SMF) |
|
IEEE 802.3 Standard |
|
G48Te, G48Pe, G48T, G48P and G48Ta
Gigabit Ethernet modules comply with the following standards |
|
|
IEEE 802.3 10BASE-T |
|
|
IEEE 802.3u 100BASE-T |
|
|
IEEE 802.3ab 1000BASE-T |
|
MSM-G8X, G24X and G48Xa Gigabit Ethernet
modules comply with the following standard |
|
|
IEEE 802.3z 1000BASE-X |
|
10GX4 10 Gigabit Ethernet module complies
with the following standard |
|
|
IEEE 802.3ae 10GBASE-X |
|
Power Supply
Options |
Both AC and DC power supplies are available. |
|
AC power supplies can run from 100Volt
to 240Volt, and deliver |
|
- 700W at 90V to 100V, or |
|
- 1200W at 200V to 220V |
|
48V DC power supplies deliver 1200W
of power |
Power over Ethernet
(PoE) 802.3af |
333 ports with 802.3af class 0 devices
supported with 6 power supplies |
432 ports with 802.3af class 1 devices
supported with 6 power supplies |
432 ports with 802.3af class 2 devices
supported with 6 power supplies |
333 ports with 802.3af class 3 devices
supported with 6 power supplies |
|
Dimensions
|
BlackDiamond
8810 Chassis: 24.47¡± high x 17.51¡± wide x 18.23¡±
deep (62.2 cm x 44.5 cm x 46.3 cm) |
BlackDiamond
8806 Chassis: 17.5¡± high x 17.51¡± wide x 18.23¡±
deep (44.45 cm x 44.5 cm x 46.3 cm) |
Power Supply:
4.75¡± high x 2.75¡± wide x 13.75¡± deep (12.1 cm x
6.99 cm x 34.9 cm) |
MSM Module
Dimensions: 1.63¡± high x 15.26¡± wide x 15.25¡±
deep (4.1 cm x 38.8 cm x 38.7 cm) |
I/O Module
Dimensions: 1.63¡± high x 15.26¡± wide x 15.25¡±
deep (4.1 cm x 38.8 cm x 38.7 cm) |
Weight
|
BlackDiamond
8810 Chassis: 79 lb (35.8 kg) |
BlackDiamond
8810 Chassis fully loaded (max): 200.5 lb (90.9
kg) |
BlackDiamond
8806 Chassis: 65 lb (29.5 kg) |
BlackDiamond
8806 Chassis fully loaded (max): 151 lb (68.5
kg) |
Power Supply:
7 lb (3.2 kg) |
MSM-G8X Module:
7.5 lb (3.4 kg) |
G48Te Module:
6.75 lb (3.06 kg) |
G48Pe Module:
6.75 lb (3.06 kg) |
G48T Module:
7.75 lb (3.5 kg) |
G48P Module:
8 lb (3.6 kg) |
G48Ta Module:
6.75 lb (3.06 kg) |
G48Xa Module:
8 lb (3.6 kg) |
G24X Module:
7.75 lb (3.5 kg) |
10G4X Module:
7.75 lb (3.5 kg) |
Power |
BlackDiamond
8810 Chassis with Fan Trays: 55 W, 48V, 1.1A
(Heat Dissipation: 188 BTU) |
BlackDiamond
8806 Chassis with Fan Trays: 45 W, 48V, 1.0
A (Heat Dissipation: 154 BTU) |
MSM-G8X Module:
150 W, 48 V, 3.125 A (Heat Dissipation: 515 BTU) |
G48Te Module:
105 W, 48V, 2.2 A (Heat Dissapation: 358 BTU) |
G48Pe Module:
110 W, 48V, 2.3 A (Heat Dissapation: 375 BTU) |
G48T Module:
105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU) |
G48P Module:
110 W, 48V, 2.3 A (Heat Dissipation: 375 BTU) |
G48Ta Module:
105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU) |
G24X Module:
105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU) |
G48Xa Module:
105 W, 48V, 2.2 A (Heat Dissipation: 38 BTU) |
10G4X Module:
115 W, 48V, 2.4 A (Heat Dissipation: 392 BTU) |
|
|
Operating
Conditions |
Operating Temperature
Range: 0° C to 40° C (32° F to 104°
F) |
Operating Humidity:
10% to 93% relative humidity, non-condensing |
Operational
Shock: 30 m/s2 (3g), 11ms, 60 Shocks |
Operational
Sine Vibration: 5-100-5 Hz @ 0.2G, 0-Peak, 0.1
Oct./min. |
Operational
Random Vibration: 3-500MHz @ 1.5g rms |
|
Regulatory/Safety
|
North
American Safety of ITE |
| UL 60950-1:2003 1st Ed., Listed Device
(US) |
| CSA 22.2#60950-1-03 1st Ed.(Canada) |
|
Complies with FCC 21CFR 1040.10 (US
Laser Safety) |
| CDRH Letter of Approval (US FDA Approval) |
| NOM/NYCE (Mexico)
|
| IEEE 802.3af 6-2003 Environment A
for PoE Applications |
European
Safety of ITE |
|
EN60950-1:2001 |
| EN 60825-1+A2:2001 (Lasers Safety) |
| TUV-R GS Mark by German Notified Body |
| 73/23/EEC Low Voltage Directive |
International
Safety of ITE |
| CB Report & Certificate per IEC
60950-1:2001+All Country Deviations |
| AS/NZX 3260 (Australia /New Zealand) |
EMI/EMC
Standards |
| North America
EMC for ITE |
| FCC CFR 47 part
15 Class A (USA) |
| ICES-003 Class
A (Canada) |
European
EMC standards |
| EN 55022:1998
Class A |
| EN 55024:1998
Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11
|
| EN 61000-3-2,3
(Harmonics & Flicker) |
| ETSI EN 300
386:2001 (EMC Telecommunications) |
|
89/336/EEC EMC
Directive |
International
EMC Certifications
|
|
CISPR
22:1997 Class A (International Emissions) |
|
CISPR 24:1997
Class A (International Immunity) |
| IEC/EN 61000-4-2
Electrostatic Discharge, 8kV Contact, 15kV Air,
Criteria A |
| IEC/EN 61000-4-3
Radiated Immunity 10V/m, Criteria A |
| IEC/EN 61000-4-4
Transient Burst, 1kV, Criteria A |
| IEC/EN 61000-4-5
Surge, 2kV, 4kV, Criteria A |
| IEC/EN 61000-4-6
Conducted Immunity |
| IEC/EN 61000-4-6
Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS,
Criteria A |
| IEC/EN 61000-4-11
Power Dips & Interruptions, > 30%, 25 periods,
Criteria C |
Country
Specific |
| VCCI Class A
(Japan Emissions) |
| AS/NZS 3548
ACA (Australia Emissions) |
| CNS 13438:1997
Class A (BSMI-Taiwan) |
| MIC Mark, EMC
Approval (Korea) |
Telecom
Standards |
|
ETSI EN 300
386:2001 (EMC Telecommunications) |
|
ETSI EN 300
019 (Environmental for Telecommunications) |
IEEE
802.3 Media Access Standards |
|
IEEE 802.3z
1000BASE-X |
|
IEEE 802.3ab
1000BASE-T |
|
IEEE 802.3ae
10GBASE-X |
|
IEEE 802.3af
Power over Ethernet |
Environmental
Standards |
|
EN/ETSI 300
019-2-1 v2.1.2 - Class 1.2 Storage |
|
EN/ETSI 300
019-2-2 v2.1.2 - Class 2.3 Transportation |
|
EN/ETSI 300
019-2-3 v2.1.2 - Class 3.1e Operational |
|
EN/ETSI 300
753 (1997-10) - Acoustic Noise |
|
ASTM D3580 Random
Vibration Unpackaged 1.5G |
|
|
|
1-year on Hardware |
|
90-days on Software |
|
|
|
|
|
|
Ordering Information
Part Number |
Description |
41011 |
BlackDiamond 8810 10-Slot Chassis
including Fan Tray |
41012 |
BlackDiamond 8806 6-Slot Chassis including
Fan Tray |
60020 |
BlackDiamond 10808/BlackDiamond 8800
700W/1200W 100-240V PSU |
60021 |
BlackDiamond 10808/BlackDiamond 8800 1200W
-48V DC PSU |
41211 |
BlackDiamond 8800 Management Switch
Module, w/8 1000BASE-X mini-GBIC I/O Ports |
41511 |
BlackDiamond 8800 48-port
10/100/1000BASE-T RJ-45 |
41512 |
BlackDiamond 8800 48-port
10/100/1000BASE-T PoE RJ-45 |
41513 |
BlackDiamond 8800 48-port
10/100/1000BASE-T RJ-45 2:1 Oversubscription, Edge |
41514 |
BlackDiamond 8800 48-port
10/100/1000BASE-T PoE RJ-45 2:1 Oversubscription, Edge |
41515 |
BlackDiamond 8800 48-port
10/100/1000BASE-T RJ-45, Advanced Aggregation |
41541 |
BlackDiamond 8800 24-port 1000BASE-X
mini-GBIC |
41542 |
BlackDiamond 8800 48-port 1000BASE-X
mini-GBIC, Advanced Aggregation |
41611 |
BlackDiamond 8800 4-port 10GBASE-X
XENPAK |
41111 |
BlackDiamond 8810 Spare Fan Tray |
65043 |
BlackDiamond 8806 Spare Fan Tray |
41112 |
BlackDiamond 8800 Spare PSU/Fan Controller
Board |
41121 |
BlackDiamond 8800 Spare Blank
Panel |
41141 |
BlackDiamond 8810 Mid Mount Kit |
41151 |
BlackDiamond 8800 Cable Management
Kit |
41311 |
BlackDiamond 8800 ExtremeXOS Core Software
Upgrade |
10110 |
10 Gigabit Ethernet XENPAK Transceiver,
850 nm, up to 300 m on Multimode Fiber, SC Connector |
10111 |
10 Gigabit Ethernet XENPAK Transceiver,
1310 nm, up to 10 km on Single-mode Fiber, SC Connector |
10112 |
10 Gigabit Ethernet XENPAK Transceiver,
1550 nm, up to 40 km on Sngle-mode Fiber, SC Connector |
10113 |
10 Gigabit Ethernet XENPAK Transceiver,
1550 nm, up to 80 km on Single-mode Fiber, SC Connector |
10114 |
10 Gigabit Ethernet WWDM XENPAK
Transceiver, 1310 nm, up to 300 m on Multi-mode Fiber and up to 10 km on a
Single-mode Fber, SC Connector |
10051 |
Mini-GBIC, SFP, 1000BASE-SX, LC
Connector |
10052 |
Mini-GBIC, SFP, 1000BASE-LX, LC
Connector |
10053 |
Mini-GBIC, SFP, Extra Long Distance SMF 70
km/21 dB Budget, LC Connector |
10056 |
Mini-GBIC, SFP, 1000BASE-BX-U, SMF (1490
nm TX/1310 nm RX Wavelength) |
10057 |
Mini-GBIC, SFP, 1000BASE-BX-D, SMF (1310
nm TX/1490 nm RX Wavelength) |
10060 |
Mini-GBIC, SFP, Dual-speed 100 FX/1000LX,
LC Connector | |
|