BlackDiamond 8800 Series

Àü¹®È­µÈ ³×Æ®¿öÅ© ÀÎÇÁ¶ó ¼Ö·ç¼ÇÀ¸·Î, ±â¾÷ IT °ü¸®ÀÚµéÀº °úµµÇÑ º¹À⼺À¸·Î ½Ã°£°ú ¸®¼Ò½º¸¦ ¼Ò¿äÇÒ ÇÊ¿ä°¡ ¾ø´Ù. Extreme Networks® ÀÇ BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °ü¸® overhead, ¿î¿µ»óÀÇ º¹À⼺°ú ÁöÃâ°æºñ¸¦ ÁÙ¿©ÁÖ´Â Çö´ë½ÄÀÇ two-tier ³×Æ®¿öÅ©¸¦ °¡Áø ÀüÅëÀûÀÇ three-tier ±¸Á¶·Î ´ëü½ÃÅ°¸ç ±â¾÷ÀÇ architecture ¸¦ ÀçÁ¤ÀÇÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ¾ðÁ¦ ¾îµð¿¡¼­³ª voice-class À̿뼺, °í¹Ðµµ PoE, ±â°¡ºñÆ® ÀÌ´õ³Ý°ú 10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» Àü´ÞÇÑ´Ù. °¡Àå ÁÖÀÇ°¡ ÇÊ¿äÇÑ ±â¾÷ ½ºÀ§ÄªÀÇ edge(Enhanced Data GSM Environment)¿¡ ÀûÇÕÇÏ´Ù.(Voice-over-IP (VoIP), video, wireless, traffic) non-blocking Æ÷Æ®´Â High Performance Cluster Computing (HPCC) À» À§ÇØ ¼öõ°³ÀÇ ¼­¹ö¸¦ »óÈ£¿¬°áÇÑ´Ù. ±¤¹üÀ§ÇÑ º¸¾ÈƯ¡À¸·Î BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Áß°ß±â¾÷À» À§ÇÑ ´ÜÀϽºÀ§Ä¡ ¼Ö·ç¼ÇÀÌ µÉ¼öµµÀÖ´Ù. full range of Layers 2 - 4 Ư¡Àº ÇÏ´Ü°ú Áß¾Ó »çÀÌÀÇ Ã¼ÁõÀ» °æ°¨½ÃÅ°¸ç ÃÊ°í¼Ó ¿¬°áÀÇ ÁýÇÕÀ» Çã¿ëÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ÇöÀçÀÇ IPv6 ¿Í Â÷¼¼´ë ±â¾÷À» À§ÇØ ÁغñÁßÀÌ´Ù.

 

 Target Applications

  • À¯, ¹«¼±, IP ÅÚ·¹Æ÷´Ï ÅëÇÕÀ» À§ÇÑ °í¹Ðµµ PoE edge ½ºÀ§Ä¡
  • High Performance Cluster (HPCC) ¸¦ À§ÇÑ ³·Àº ´ë±â½Ã°£ Á¢¼ÓÀ» Á¦°øÇÏ´Â »óÈ£¿¬°á ½ºÀ§Ä¡
  • ÁßÇü ³×Æ®¿öÅ©·ÎÀÇ ´ÜÀÏ ½ºÀ§Ä¡ ³×Æ®¿öÅ© ¼Ö·ç¼Ç
  • ÀüÅëÀûÀÎ ±â°¡ºñÆ®³ª 10±â°¡ºñÆ® ÀÌ´õ³Ý ÁýÇÕ½ºÀ§Ä¡

 

Voice-Class Availability

  • ÃæºÐÇÑ ½Ã½ºÅÛ µðÀÚÀÎ
  • Modular ExtremeXOS¢â Operating System (OS) for non-stop operations
  • ÀÌ´õ³Ý ÀÚµ¿º¸È£ ½ºÀ§Äª(EAPS) ź·ÂÀûÀÎ ÇÁ·ÎÅäÄÝ

 

High-Performance Connectivy

  • Voice and wireless connectivity
  • 570 Mpps ¸¦ Áö¿øÇÏ´Â ´ëÇü½ºÀ§Äª ´É·Â
  • ´Ù¼ö ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ Åº·ÂÀûÀÎ Á¢¼Ó¼º

 

Comprehensive Security Providing Defense-In-Depth

  • Directory-integrated link security
  • ³×Æ®¿öÅ© ħÀÔ¿¡ ÀÀ´ëÇϴ ħÀÔÂ÷´Ü ÀÀ´ë
  • °­È­µÈ ³×Æ®¿öÅ© ÀÎÇÁ¶ó

 

Voice-Class Availability

°í¼öÇà ³×Æ®¿öÅ© Á¢¼ÓÀ¸·Î, Á¢¼Ó·¹À̾¼­ pc¿Í IP ÅÚ·¹Æ÷´Ï¿¡ ¿¬°áÇϰųª Ŭ·¯½ºÅÍ »ó¿¡¼­ ¼­¹öµéÀ» »óÈ£¿¬°á ÇÏ´øÁö °£¿¡ ¸Å¿ì

À¯¿ëÇÏ´Ù. BlackDiamond 8800 modular ½ºÀ§Äª ±ºÀº ±¤º¡À§ÇÑ Çϵå¿þ¾î redundancy(Áߺ¹) ¿Í ÁýÇÕ ¾îÇø®ÄÉÀ̼ǿ¡ ¿ä±¸µÇ´Â

³×Æ®¿öÅ© º¹±¸¸¦ Á¦°øÇÏ´Â modular OS¢âExtremeXOS¢â ¸¦ ÅëÇÕÇÏ¿´´Ù.

 

Redundant System Design

Redundant Management Modules

BlackDiamond 8800 modular ½ºÀ§Äª ±ºÀº °ü¸®½ºÀ§Ä¡ ¸ðµâ(MSM) ÀÌ ¿À·ù°¡ ¹ß»ýÇÑ´Ù¸é, second MSM ÀÌ ÀÚµ¿ÀûÀ¸·Î Àüü½ºÀ§Ä¡ÀÇ °ü¸®Ã¥ÀÓÀ»

Àμö¹Þ±âÀ§ÇØ ÀÚµ¿ ´ëüÀÛµ¿ mechanism À¸·Î ±¸¼ºµÇ¾îÀÖ´Ù. ÀÌƯ¡Àº À½¼º°ú mission-critical ¾îÇø®ÄÉÀ̼ÇÀ» ¿î¿µÇÏ´Â ³×Æ®¿öÅ©¿¡ ÇʼöÀûÀÌ´Ù.

 

Advanced Chassis Design for Availability

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °í¸³µÈ Á¦¾î¿Í data plane, ÆÄ¿öºÐ¹è¸¦ À§ÇÑ redundant controller ¿Í fan control, ³×Æ®¿öÅ©¿¡ ¿µÇâÀ»

¹ÌÄ¡±âÀü¿¡ ¾ÇÀÇÁ¢ Á¢¼ÓÀ» ½Äº°Çϴ ȯ°æ ¸ð´ÏÅ͸µ °°Àº °íÀ̿뼺 ¼³°è¿ä¼Ò¿¡ ÀÇÇØ ÀÌÇàµÇ´Â passive backplane À» Æ÷ÇÔÇÑ´Ù.

 

Redundant Load Sharing Power Supplies

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 6°³ÀÇ ³»ºÎ ÆÄ¿ö ¼­ÇöóÀ̸¦ µ¿½Ã¿¡ °øÀ¯ÇÏ¿© ·ÎµåÇÒ¼öÀÖ´Â ¿©À¯ÀÖ´Â ÆÄ¿ö ȯ°æ¼³Á¤À» Áö¿øÇÑ´Ù.

2 +1 ȯ°æ¼³Á¤ÀÇ 3°³ÀÇ ÆÄ¿ö ¼­ÇöóÀÌ´Â ±â°¡ºñÆ®³ª 10 ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®·Î ¸ðµÎ ÀûÀçµÈ chassis ·Î °ø±ÞÇÒ¼öÀÖ´Ù.

µ¡ºÙ¿©¼­, ¿ÜºÎÆÄ¿ö Æ®·¹À̸¦ ÇÊ¿ä·Î ÇÏÁö¾Ê°í, 3°³ÀÇ ÆÄ¿ö¼­ÇöóÀÌ´Â Ä¿´Ù¶õ PoE ±¸ÇöÀ» Áö¿øÇϱâ À§ÇØ ÀÌ¿ë°¡´ÉÇÏ´Ù.

 

Redundant Cooling Fans in a Hot-Swappable Fan Tray

A tray of nine/six fans Àº BlackDiamond 8800 ½Ã¸®Áî »þ½Ã¿¡¼­ ÃæºÐÇÑ cooling À» Àü´ÞÇÑ´Ù.

fan tray ÀÚü°¡ hot swappable À̶ó¼­, BlackDiamond 8800 ½Ã¸®Áî ½Ã½ºÅÛÀº fan tray ±³Ã¼µÇ´Â µ¿¾È¿¡µµ ¿î¿µÀÌ Áö¼ÓµÈ´Ù.

 

Modular Operating System for Non-stop Operations

True Preemptive Multitasking and Protected Memory

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °¢±â·ÎºÎÅÍ º¸È£µÇ´Â ºÐ¸®µÈ OS ÇÁ·Î¼¼½º¿¡¼­ ¿î¿µÇϱâÀ§ÇÑ OSPF ¿Í ½ºÆÐ´× Æ®¸®°°Àº °¢±â ¸¹Àº

¾îÇø®ÄÉÀ̼ÇÀ» Çã¿ëÇÑ´Ù. ÀÌ°ÍÀº Çâ»óµÈ ½Ã½ºÅÛ ¹«°á¼º°ú DoS °ø°ÝÀ¸·ÎºÎÅÍ °íÀ¯ÀÇ ¹æ¾î¸¦ °¡Á®¿Â´Ù.

 

Process Monitoring and Restart

ExtremeXOS ´Â process ¸ð´ÏÅ͸µ°ú restart ¸¦ ÀÌ¿ëÇÏ¿© ³×Æ®¿öÅ© À̿뼺À» Áõ°¡½ÃŲ´Ù.

°¢±â µ¶¸³ÀûÀÎ OS ÇÁ·Î¼¼½º´Â ½Ç½Ã°£À¸·Î °¨½ÃµÈ´Ù. ¸¸¾à ÇÁ·Î¼¼½º°¡ ¹ÝÀÀÀÌ ¾ø°Å³ª ¿î¿µÀÌ ÁßÁöµÈ´Ù¸é, ÀÚµ¿À¸·Î Àç½ÃÀ۵ȴÙ.

 

Loadable Software Modules

ExtremeXOS ÀÇ ¸ðµâ·¯ ¼³°è´Â ³×Æ®¿öÅ©¿¡¼­ ³ôÀº À̿뼺À» °¡Á®´ÙÁÖ´Â °³º°Àû ¼ÒÇÁÆ®¿þ¾î ¸ðµâÀÇ ¾÷±×·¹À̵带 Çã¿ëÇÑ´Ù.


High Availability Network Protocols

Ethernet Automatic Protection Switching (EAPS)

EAPS ´Â ÀüÅëÀû À½¼º ³×Æ®¿öÅ©·Î ºÎÅÍÀÇ À¯ÀúµéÀÌ ±â´ëÇϴ ź·Â¼º°ú ÀÛ¾÷½Ã°£ÀÇ ·¹º§À» Á¦°øÇÏ´Â IP ³×Æ®¿öÅ©¸¦ Á¦°øÇÑ´Ù.

EAPS ´Â ½ºÆд×Æ®¸®³ª Rapid ½ºÆд×Æ®¸® ÇÁ·ÎÅäÄݺ¸´Ù ¿ì¼öÇϸç, sub-second(50 milliseconds ÀÌÇÏ) ȸº¹À» Á¦°øÇϸç

VLANs, ³×Æ®¿öÅ© ³ëµå³ª ³×Æ®¿öÅ© topology ÀÇ ¼ö¿¡ °ü°è¾øÀÌ ²ÙÁØÇÑ ´ëüÀÛµ¿À» Àü´ÞÇÑ´Ù.

EAPS ´Â ³×Æ®¿öÅ©°¡ ¸µÅ©¿À·ù·Î ºÎÅÍ °ÅÀÇ Åõ¸íÇÏ°Ô È¸º¹µÇ±â ¶§¹®¿¡

´ëºÎºÐÀÇ »óȲ¿¡¼­ VoIP ´Â ¶³¾îÁöÁö ¾ÊÀ¸¸ç µðÁöÅÐ ºñµð¿À °ø±ÞÀº µ¿°áµÇ°Å³ª pixelize È­ µÇÁö ¾Ê´Â´Ù.

 

Spanning Tree/Rapid Spanning Tree Protocols

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ½ºÆд×Æ®¸®(802.1D), Per VLAN ½ºÆд×Æ®¸®(PVST+), Rapid ½ºÆд×Æ®¸®(802.1w) ¿Í

Layer 2 ź·Â¼ºÀ» À§ÇÑ ½ºÆд×Æ®¸®(802.1s) ÇÁ·ÎÅäÄÝÀÇ ´ÙÁß¿ä¼Ò¸¦ Á¦°øÇÑ´Ù.

 

Software Enhanced Availability

Software enhanced availability ´Â ³×Æ®¿öÅ©ÀÇ ÀÎÇÁ¶ó ÀϺΰ¡ ´Ù¿îµÇ¾úÀ»¶§ Á¶Â÷µµ À¯Àú°¡ ³×Æ®¿öÅ©¿¡ ¿¬°á»óÅ·Π³²¾ÆÀÖ°Ô ÇØÁØ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â OSPF ,VRRP ,ESRP(ESRP supported in Layer 2 or Layer 3) ¿Í °°Àº Áøº¸µÈ Layer 3 ÇÁ·ÎÅäÄÝÀ» ÀÌ¿ëÇÏ¿©

¾÷¸µÅ© ¿¬°á»óÅ¿¡¼­ ²ÙÁØÈ÷ »óÅÂÁ¡°ËÀ» ÇÑ´Ù.

 

Equal Cost Multipath

Equal Cost Multipath ´Â ÃæºÐÇÑ ´ëüÀÛµ¿À» Áö¿øÇÏ´Â µ¿¾È¿¡ ¾÷¸µÅ©¸¦ ¼öÇà°ú ºñ¿ëÀý°¨À» À§ÇÑ ·Îµå¹ë·±½º°¡ µÇµµ·Ï ÇÑ´Ù.

¾÷¸µÅ© ¿À·ù½Ã¿¡, Æ®·¡ÇÈÀº ÀÚµ¿À¸·Î ³²ÀÌÀÖ´Â ¾÷¸µÅ©·Î ÀüȯµÇ¸ç ¿¬°á»óÅ´ À¯ÁöµÈ´Ù.

 

Link Aggregation (802.3ad)

Cross module link aggregation Àº ´ÜÀÏÁö¿ª ¿¬°á¿¡¼­ 8°³ ¸µÅ©±îÁö, Áö¿ª¿¬°á¸¶´Ù ÃæºÐÇÑ ´ë¿ªÆøÀÎ 80 Gbps±îÁö trunking À» °¡´ÉÇÏ°ÔÇÑ´Ù.

 

High-Performance Connectivity

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ³×Æ®¿öÅ© ÇÏ´Ü ÀåºñÁõ°¡(IP telephones, ¹«¼±AP µî) °°Àº ³×Æ®¿öÅ· °æÇâÀ» ¹Ý¿µÇϱâ À§ÇÑ

°í¼öÇà, ºñ¿ëÀý°¨ ¿¬°á¼ºÀ» Àü´ÞÇÑ´Ù. ÀÌ·¯ÇÑ ³×Æ®¿öÅ· °æÇâÀº µ¥½ºÅ©Å¾°ú »óÈ£¿¬°á ÅäÆú·ÎÁö·Î½á 10±â°¡ºñÆ® ÀÌ´õ³Ý ÀÌ¿ëÀ» À§ÇØ

±â°¡ºñÆ® ÀÌ´õ³ÝÀ» À§ÇÑ ¿ä±¸»çÇ×À» ÃæÁ·ÇÑ´Ù.

 

 

Voice and Wireless Connectivity

Voice Grade Connections

Granular QoS, low latency(³·Àº ´ë±â½Ã°£), low jitter(³·Àºº¯µ¿)´Â voice quality ¿¬°áÀ» °¡´ÉÇÏ°ÔÇÑ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Æ÷Æ®¸¶´Ù 8°³ÀÇ queue ¿Í ¿ì¼±¼øÀÇ ¼³Á¤°ú ³ôÀº ¿ì¼±¼øÀÇ traffic¢âpolicing À̳ª ÀԷºκРÁ¦ÇÑ,

802.1q tagging °ú DiffServ marking, ¿øÈ°ÇÑ Àü¼ÛÀ» ´Ù·ê¼ö ÀÖ´Â QoS ¸¦ Áö¿øÇÑ´Ù.

 

High-Density PoE

PoE ´Â BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡°¡ ´Ù¼ö IPÅÚ·¹Æ÷´Ï¿Í ¹«¼± AP ¹èÄ¡¸¦ Áö¿øÇÏ°ÔÇÑ´Ù.

BlackDiamond 8810 Àº ´ÜÀÏ 14RU »þ½Ã 3Æ÷Æ®¿¡¼­ 333 Ŭ·¡½º¸¦ Áö¿øÇÒ¼ö Àְųª Ŭ·¡½º 1 ȤÀº 2 power ·Î ´ÜÀÏ »þ½Ã¿¡¼­ 432 PoE port ·Î ÃÖ´ë

°ø±ÞÀÌ °¡´ÉÇÏ´Ù. Class 1, 2 ȤÀº 3 Àåºñµé·Î ¸ðµÎ ÀûÀçµÈ BlackDiamond 8800 ½ºÀ§Ä¡¿¡ µ¿·ÂÀ» °ø±ÞÇϱâ À§ÇØ ¿ÜºÎ power tray °¡ ÇÊ¿äÄ¡¾Ê´Ù.

 

Link Layer Discovery Protocol Support

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ±â¾÷³×Æ®¿öÅ©ÀÇ ¹®Á¦ÇØ°áÀ» °£´ÜÈ÷ ÇϱâÀ§ÇØ Link Layer Discovery Protocol (LLDP) ¸¦ ÅëÇÕÇϸç

Á¤È®ÇÑ ³×Æ®¿öÅ© ÅäÆú·ÎÁö ¹ß°ß°ú À¯ÁöÇϱâÀ§ÇØ ³×Æ®¿öÅ© °ü¸®ÅøÀÇ ´É·ÂÀ» Çâ»ó½ÃŲ´Ù.

°ü¸®¿Í Á¢¼Ó¼ºÀ» ±Ø´ë·Î °£·«È­ ÇÔ¿¡ ÀÇÇؼ­ ÁýÇÕ³×Æ®¿öÅ©ÀÇ º¹À⼺°ú ºñ¿ëÀ» ÁÙ¿©ÁØ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ±â¾÷µéÀÌ non-disruptive Plug-and-Play·Î »õ·Î¿î Á¢¼ÓÀåºñ¸¦ Ãß°¡ÇÒ¼ö ÀÖµµ·Ï ÇÏ¿© ÁýÇÕ ¾îÇø®ÄÉÀ̼ÇÀÇ

±¹¸éÀ» ¸¶·ÃÇß´Ù. À½¼º°ú ¹«¼± ¼­ºñ½º´Â Ä¿´Ù¶õ ³×Æ®¿öÅ© ¾÷±×·¹ÀÌµå ¾øÀÌ ½±°Ô ÀÌÇàµÉ¼öÀÖ´Ù.

 

High-Density, Line-Rate Connectivity

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 1,200 non-blocking ±â°¡ºñÆ® Æ÷Æ®¸¦ Áö¿øÇϰųª °ÅÀÇ ¹é°³ÀÇ non-blocking 10 ±â°¡ºñÆ® ÀÌ´õ³Ý Æ÷Æ®¸¦ ´ÜÀÏ

seven foot rack ¿¡¼­ Áö¿øÇϸç, cluster(¹«¸®) ¸¦ À§ÇÑ ¸Å¿ì ºñ¿ëÀý°¨ÀûÀÎ ¿¬°á¿É¼ÇÀ» Àü´ÞÇÑ´Ù.

 

Jumbo Frame Support

jumbo frame À» Áö¿øÇÏ´Â °ÍÀº ³×Æ®¿öÅ© ¼öÇàÀ» ÃÖÀûÈ­ ÇϱâÀ§ÇÑ cluster computing ¾îÇø®ÄÉÀ̼ÇÀ» Çã¿ëÇÑ´Ù.

 

IPv6 Packet Forwarding Support

IPv6 ´Â »õ·Î¿î IPÁÖ¼Ò¸¦ trillion(100°æ) ¸¸Å­À̳ª »ç¿ë°¡´ÉÇÏ°Ô ¸¸µé¸ç, ´õ ³ªÀº ÁÖ¼ÒÇÒ´ç, ÁÖ¼ÒÁýÇÕ ±×¸®°í ±²ÀåÈ÷ ¶Ù¾î³­ end-to-end ¿¬°á¼º°ú

¼­ºñ½º¸¦ Á¦°øÇϴ Ư¡µéÀ» Çã¿ëÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ÇöÀçÀÇ IPv6 ¸¦ Áö¿øÇÏ¸ç ±â¾÷ÀÌ IPv6 Æ®·¡ÇÈÀ» ´Ù·ê¼öÀÖ°Ô ÇØÁÖ¸ç,

ÀÌÆ®·¡ÇÈÀº ¾î¶² ³×Æ®¿öÅ©¿¡µµ µé¾î°¥¼öÀÖ´Ù.

 

Large Switching Capacity

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 800 Gbps ½ºÀ§Ä¡ ±¤´ë¿ªÆøÀ»  Àü´ÞÇϸç 570 Mpps ÀÌ»óÀÇ Layer 2- Layer 3 Çϵå¿þ¾î Àü¼Û·üÀ» Àü´ÞÇÑ´Ù.

  • 800 Gbps switch fabric bandwidth
  • 48 Gbps per slot capacity
  • Over 570 Mpps Layer 2/Layer 3 hardware forwarding rate
  • Local switching on every I/O module
Module Name
G48Te
G48Pe
G48Ta
G48Xa
G48T
G48P
G48X
MSM-G8X1
10G4X
10/100/1000BASE-T ports
48
48 PoE
48
/
48
48 PoE
/
/
/
1000X mini-GBIC ports
/
/
/
48
/
/
24
8
 
10GBASE-X XENPAK ports
/
/
/
/
/
/
/
/
4
Backplane capacity (Gbps) 2*MSM/1*MSM
24/12
24/12
48/24
48/24
48/24
48/24
48/24
12
48/24
Load Sharing Groups
128
128
128
128
128
128
128
128
32
Jumbo Frame per port2
Per Port
Per Port
Per Port
Per Port
Per System
Per System
Per System
Per System
Per System
Layer 2 MAC FDB
8K per module
8K per module
16K per module
16K per module
16K per module
16K per module
16K per module
16K per module
16K per module
IPv4 LPM entries
512
512
12K
12K
8K
8K
8K
8K
8K
IPv4 Host entries
2K
2K
8K
8K
8K
8K
8K
8K
8K
IPv6 forwarding3
Hardware
Hardware
Hardware
Hardware
Software
Software
Software
Software
Software

Figure 2: Multiple Connectivity Options
1 The 8-port gigabit Ethernet ports on MSM-G8X
2 Future Release
3 Future Release for harware-based IPv6 routing

 

 

Flexible Connectivity

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ƯÁ¤ ¾îÇø®ÄÉÀ̼ǿ¡ ÃÖÀûÈ­µÈ °íź·Â¼º ¿¬°á¿É¼ÇÀ» Á¦°øÇÑ´Ù.

"e" series Gigabit ÀÌ´õ³Ý ¸ðµâÀº PoE ¿©ºÎ »ó°ü¾øÀÌ ±â°¡ºñÆ® edge(ÇÏ´Ü) Á¢¼Ó¼ºÀ» Á¦°øÇϱâ À§ÇØ ¼³°èµÇ¾úÀ¸¸ç,

"a" series Gigabit ÀÌ´õ³Ý ¸ðµâÀº ±â°¡ºñÆ® ÁýÇÕÀ̳ª ¼­¹ö½ºÀ§Äª ȯ°æ¿¡¼­ ³ôÀº scalable(ÃøÁ¤°¡´ÉÇÑ) ¿¬°á¼ºÀ» Á¦°øÇϱâÀ§ÇØ ¼³°èµÇ¾ú´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡¸¦ ÀÌ¿ëÇÑ ´Ù¼ö¿¬°á ¿É¼ÇÀ» Figure 2 ¿¡ ¿ä¾àÇÏ¿´´Ù.

 

Comprehensive Security Using Defense-in-Depth

º¸¾È ³×Æ®¿öÅ©¸¦ ÀÌÇàÇÑ´Ù´Â °ÍÀº Áß¾Ó»Ó¸¸ ¾Æ´Ï¶ó ³×Æ®¿öÅ© ¿Ü°¢¿¡¼­µµ ¹æ¾î¸¦ Á¦°øÇϴ°ÍÀ» ÀǹÌÇÑ´Ù.

Extreme Networks Sentriant¢â Á¦Ç°±º°ú ÇÔ²² ÀÛµ¿ÇÔÀ¸·Î½á, BlackDiamond 8800 ½ºÀ§Ä¡´Â ¾Ë·ÁÁö°Å³ª ±×·¸Áö ¾ÊÀº À§ÇùÀ¸·ÎºÎÅÍ

³×Æ®¿öÅ©¸¦ º¸È£Çϴµ¥ À־ defense-in-depth strategy ¸¦ ÀÌ¿ëÇÑ´Ù.

 

Directory-Integrated Link Security

Intelligent Network Access

Áö´ÉÀûÀÎ ³×Æ®¿öÅ© Á¢¼ÓÀº À¯Àú½ÂÀΰú ÀÌ¿ëÁ¤Ã¥À» °­È­ÇÑ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â 802.1x agent-based Á¢±ÙÀ» Á¦°øÇÔÀ¸·Î½á ±¤¹üÀ§ÇÑ ³×Æ®¿öÅ© ·Î±ä ¿É¼Ç, °Ô½ºÆ®¸¦ À§ÇÑ À¥±â¹Ý ·Î±ä´É·Â,

ÀåÄ¡¸¦ À§ÇÑ MAC ±â¹Ý ÀÎÁõ¸ðµ¨À» Áö¿øÇÑ´Ù.

ÀÌ·¯ÇÑ ³×Æ®¿öÅ© ·Î±ä ¸ðµå·Î½á, ½ÂÀÎµÈ À¯Àú¿Í Àåºñµé¸¸ ³×Æ®¿öÅ© Á¢¼ÓÀÌ °¡´ÉÇϸç Àû´çÇÑ VLAN À» ÇÒ´ç¹Þ´Â´Ù.

 

Multiple Supplicant Support

ºÐÇÒµÈ Æ÷Æ®´Â ³×Æ®¿öÅ©¿¡¼­ ÀáÀçÀûÀ¸·Î Ãë¾àÇÔÀ» ³ªÅ¸³½´Ù.

½ºÀ§Ä¡¿¡¼­ Multiple Supplicant ´É·ÂÀº µ¶Æ¯ÇÑ ½ÂÀÎÀ» Çã¿ëÇÏ¸ç ºÐÇÒµÈ Æ÷Æ®¿¡¼­ °¢±â À¯Àú¸¦ À§ÇÑ Àû´çÇÑ Á¤Ã¥°ú VLANÀ» Àû¿ëÇÑ´Ù.

Multiple supplicant ´Â º¸¾È IP ÅÚ·¹Æ÷´Ï¿Í ¹«¼±Á¢¼ÓÀ» Áö¿øÇÑ´Ù. ÁýÇÕ³×Æ®¿öÅ© ¼³°è´Â Á¾Á¾ ºÐÇÒµÈ Æ÷Æ®ÀÇ ÀÌ¿ëÀ» ¼ö¹ÝÇÑ´Ù.

 

PC plugging into an IP telephone

´Ù¼öÀ¯ÀúµéÀº ¹«¼±AP ȤÀº Layer 2 ½ºÀ§Ä¡/Çãºê¸¦ ÅëÇؼ­ Á¢¼ÓµÇ¹Ç·Î °°Àº ¹°¸®Àû PoE Æ÷Æ®¸¦ °øÀ¯ÇÑ´Ù.

 

Host Integrity Checking

È£½ºÆ® ¹«°á¼º °Ë»ç´Â °¨¿°µÇ°Å³ª ¸í·É¿¡ ºÒÀÀÇÏ´Â ÀåºñµéÀ» ³×Æ®¿öÅ©·ÎºÎÅÍ °Ý¸®½ÃŲ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Trusted Computing

Group ÀÇ ¸ðµ¨À» ±â¹ÝÀ¸·ÎÇÑ È£½ºÆ® ¹«°á¼ºÀ̳ª endpoint(¸ñÀûÁö) ¹«°á¼º ¼Ö·ç¼ÇÀ» Áö¿øÇÑ´Ù.

 

Threat Detection and Response

sFlow®

sFlow ´Â ¸ðµçÀåÄ¡¿¡¼­ µ¿½Ã¿¡ ¾îÇø®ÄÉÀÌ¼Ç level Æ®·¡ÇÈ È帧À» sample ÇϱâÀ§ÇÑ ´É·ÂÀ» Á¦°øÇÏ´Â sampling ±â¼úÀÌ´Ù.

"e" ½Ã¸®Áî¿Í "a" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº Çϵå¿þ¾î ¿¡¼­ sFlow sampling À» Áö¿øÇÑ´Ù.

 

Port Mirroring

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â many-to-one °ú cross module port mirroring À» Áö¿øÇÑ´Ù.

ºÐ¼®À» À§ÇÑ Ä§ÀÔÂ÷´Ü Àåºñ¿Í °°Àº ¿ÜºÎ³×Æ®¿öÅ© Àåºñ·Î ÇâÇÑ mirror Æ®·¡ÇÈ¿¡ ÀÌ¿ëµÉ¼ö Àְųª ³×Æ®¿öÅ© °ø°Ý¿¡ ´ëÀÀÇÒ¶§ Áø´ÜÅø·Î½á

³×Æ®¿öÅ© °ü¸®ÀÚ¿¡ ÀÇÇØ È°¿ëµÈ´Ù.

 

Line-Rate Access Control Lists (ACLs)

ACLs ´Â ³×Æ®¿öÅ© ÀÚ¿ø È°¿ëÀ» Á¦¾îÇÏ¸ç ³×Æ®¿öÅ© º¸¾È°ú ¹æ¾î¸¦ À§ÇÑ °¡Àå °­·ÂÇÑ ÅøÁßÀÇ ÇϳªÀÌ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â MAC address or IP source/destination address or TCP/UDP port number ¿Í °°Àº Layer 2, 3 ³ª

4-header information À» ±â¹ÝÇÑ Çϵå¿þ¾î ±â¹Ý ACLs ¸¦ Áö¿øÇÑ´Ù.

"e" ½Ã¸®Áî¿Í "a" ½Ã¸®Áî ¸ðµâÀº ±â°¡ºñÆ® ÀÌ´õ³ÝÀÇ 24-port block ¸¶´Ù Áß¾ÓÁýÁßÇü ACL ¸®¼Ò½º¸¦ Á¦°øÇÔ¿¡ ÀÇÇؼ­ ¶Ù¾î³­ ACL È®À强À» Á¦°øÇÑ´Ù.

Áß¾ÓÁýÁßÇü ¸®¼Ò½º´Â ´Ù¼öÆ÷Æ®¸¦ ÅëÇØ °øÀ¯µÉ¼öÀÖ´Ù. ±×·¯¹Ç·Î ´ÜÀÏ Çϵå¿þ¾î ¸®¼Ò½º´Â 24 Æ÷Æ®·Î ºÐ¹èµÉ¼öÀÖ´Ù.

"e" ½Ã¸®Áî¿Í "a" ½Ã¸®Áî ¸ðµâÀ» À§ÇÑ ACL ¿£ÁøÀº ¶ÇÇÑ 16°³ ±îÁöÀÇ µ¶Æ¯ÇÑ TCP/UDP port range ¸¦ °áÇÕÇϱâÀ§ÇÑ ´É·ÂÀ» Á¦°øÇÑ´Ù.

±×·¡¼­ Á÷¼±»óÀ¸·Î TCP/UDP port °ªÀÌ setting µÉ¶§ Á¶Â÷µµ ´ÜÁö ÇϳªÀÇ ´ÜÀÏ Çϵå¿þ¾î ¸®¼Ò½º¸¸ÀÌ ¿ä±¸µÈ´Ù.

 

Hardened Network Infrastructure

Denial of Service (DoS) Protection

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â DoS °ø°ÝÀ» ÈǸ¢ÇÏ°Ô ´Ù·é´Ù. ½ºÀ§Ä¡°¡ CPU ÀÔ·Â queue ¿¡¼­ ºñÁ¤»ó ÀûÀ¸·Î ¸¹Àº¼öÀÇ ÆÐŶÀ» ŽÁöÇÑ´Ù¸é,

cpu µµÀÛÀ¸·Î ºÎÅÍ À̵éÆÐŶÀ» ÀÚµ¿À¸·Î ÁßÁö½ÃÅ°´Â ACLs¸¦ ¼ÒÁýÇÒ°ÍÀÌ´Ù. ¾ó¸¶ÈÄ¿¡, ACLs´Â Á¦°ÅµÈ´Ù. ¸¸¾à °ø°ÝÀÌ °è¼ÓµÈ´Ù¸é

´Ù½Ã¼³Ä¡µÉ °ÍÀÌ´Ù.

Module Name
G48Te
G48Pe
G48Ta
G48Xa
G48T
G48P
G24X
MSM-G8X
10G4X
ACL hardware resources1
Centralized per 24-port block
Centralized per 24-port block
Centralized per 24-port block
Centralized per 24-port block
Per Port Basis
Per Port Basis
Per Port Basis
Per Port Basis
Per Port Basis
Policy based routing2
Yes
Yes
Yes
Yes
No
No
No
No
No
sFlow sampling
Hardware
Hardware
Hardware
Hardware
Software
Software
Software
Software
Software

Figure 3: Security Features
1 For more detailed description on Access Control List feature, please refer to the ExtremeXOS 11.5 Concept Guide
(http://www.extremenetworks.com/services/documentation/swuserguides.asp)
2 Policy-based routing should be supported on the module where packet ingresses on its port. Egress port does not require policy-based routing support on the module.

 

 

Policy Based Routing

Policy-based routing Àº ³×Æ®¿öÅ©ÀÇ Æ®·¡ÇÈ È帧À» customize(»ç¿ëÀÚ ÁöÁ¤) ÇϱâÀ§ÇØ ³×Æ®¿öÅ© °ü¸®ÀÚ¸¦ À§ÇÑ À¶Å뼺ÀÖ´Â mechanism À» Á¦°øÇÑ´Ù.

½ºÀ§Ä¡¿¡¼­ ȯ°æ¼³Á¤µÈ ACLs ´Â ±×µéÀÇ º¸Åë °æ·Î·ÎºÎÅÍ ´Ù¸¥ ¹°¸®Àû ½ºÀ§Ä¡ Æ÷Æ®·Î ÀüȯÇÒ¼öÀÖ´Ù.

ÆÐŶÀº QoS, VLAN, IP ÁÖ¼Ò, ÇÁ·ÎÅäÄÝ, Æ÷Æ®¹øÈ£³ª ´Ù¸¥Ç¥Áصé°ú °°Àº ACLs match condition ¿¡ ÀÏÄ¡Çϴ°ÍÀÌ ¼±ÅõȴÙ.

"e" ½Ã¸®Áî¿Í "a" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº policy-based routing ´É·ÂÀ» Á¦°øÇÑ´Ù.

 

ASIC-based Longest Prefix Match (LPM)

LPM routing Àº »õ·Î¿î È帧À» ¹è¿ì´Â control plane software ÀÇ Çʿ伺À» °æ°¨½ÃÅ°¸ç ³×Æ®¿öÅ©´Â DoS °ø°Ý¿¡ ź·ÂÀûÀ¸·Î µÈ´Ù.

 

Secure Management

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡¿¡ ÀÇÇØ Áö¿øµÇ´Â SSH2 ,SCP ,SNMPv3 ¿Í°°Àº ÇÁ·ÎÅäÄÝÀÇ ÀÌ¿ëÀº °ü¸®¿î¿µ°ú man-in-the-middle attack ÀÇ

¿ä°ÝÀ» ¹æÁöÇÑ´Ù,

 

MD5 Authentication of Routing Protocols

Routing ÇÁ·ÎÅäÄÝÀÇ MD5 ½ÂÀÎÀº °ø°ÝÀÚµéÀÌ À¯È¿¸Þ½ÃÁö º¯°æ°ú routing session À» °ø°ÝÇϴ°ÍÀ» ¸øÇÏ°ÔÇÑ´Ù.

 

 

Target Applications

 

Application and Recommended Connectivity Options

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´Ù¾çÇÑ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ÃÖ»óÀ¸·Î ¾Ë¸Â´Â ³×Æ®¿öÅ· ¼Ö·ç¼ÇÀ» Á¦°øÇÏ´Â ´Ù¾çÇÑ ¿¬°á¿É¼ÇÀ» °¡Áö°íÀÖ´Ù.

"e" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº gigabit PoE edge, µ¥½ºÅ©Å¾ ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ±â°¡ºñÆ®¿Í °°Àº edge ¾îÇø®ÄÉÀ̼ǿ¡ ÃÖ»óÀÌ´Ù.

"a" ½Ã¸®Áî ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº(G48Ta and G48Xa) HPCC ¿Í ÁýÇÕ ¾îÇø®ÄÉÀ̼ǰú °°Àº ¾îÇø®ÄÉÀ̼ǿ¡¼­ ¿ä±¸¸¦ ¸¸Á·½ÃÅ°´Â °í È®À强À»

Á¦°øÇÑ´Ù. ¾Æ·¡ íƮ´Â BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡°¡ Á¦°øÇÏ´Â ³×°³ÀÇ ÁÖ¿ä ¾îÇø®ÄÉÀ̼ǿ¡ ÀÇÇÑ ±ÇÀå¸ðÆ« ŸÀÔÀ» ¼³¸íÇÑ´Ù.

 

High-Density PoE Edge Switch for Integrated Wired, Wireless and IP Telephony

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´ÙÀ½°ú °°Àº ³×Æ®¿öÅ· °æÇâ¿¡ ÀÌÇØ ÁÖ¾îÁø °í¼º´É°ú ºñ¿ëÀý°¨Àû ¿¬°á¼ºÀ» Àü´ÞÇÑ´Ù.

Áõ°¡ÇÏ´Â IP telephone, ¹«¼±AP, ³×Æ®¿öÅ© ÇÏ´ÜÀÇ ´Ù¸¥Àåºñµé, µ¥½ºÅ©Å¾À» ÇâÇÑ ±â±âºñÆ® ÀÌ´õ³Ý Á¢¼Ó, »óÈ£¿¬°á ±â¼ú·Î½á

±â°¡ºñÆ®¿Í 10±â°¡ºñÆ® ÀÌ´õ³ÝÀÇ ÀÌ¿ë

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â ´ÜÀÏÅëÇÕ Á¢¼Ó·¹À̾î·Î ÅëÇյDZâ À§ÇØ ÀüÅëÀûÀÎ edge layer ¿Í ³×Æ®¿öÅ©ÀÇ ÁýÇÕ layer ¸¦ Çã¿ëÇÑ´Ù.

edge ¾îÇø®ÄÉÀ̼ǿ¡¼­, G48Te ¿Í G48Pe ¸ðµâÀº BlackDiamond 8800 ¸ðµâÀÇ ÃÖ»óÀÇ edge Á¢¼Ó¼ºÀ» Á¦°øÇÑ´Ù.

 

High Performance Cluster Computing

HPCC ´Â Ä¿´Ù¶õ °è»ê»óÀÇ ¹®Á¦¸¦ ÇØ°áÇϱâ À§ÇØ »óÈ£º¸¿ÏÀûÀ¸·Î ÀÛµ¿ÇÏ´Â ¼ö¹é ȤÀº ¼öõ°³ÀÇ ¼­¹ö·Î ±¸¼ºµÇ¾îÀÖ´Ù.

»ó´ëÀûÀ¸·Î Àú·ÅÇÏ¸ç ¼ÒÇüÈ­µÈ 1RU ¼­¹öÀÇ ÀÌ¿ëÀ¸·Î, °Å´ëÇÑ ¾çÀÇ Ã³¸®ÆÄ¿ö´Â »ó´ëÀûÀ¸·Î ÀÛÀº footprint(¹üÀ§) ·Î µé¾î°¡¼­ ºñ¿ëÀý°¨ÀûÀ¸·Î µÉ¼öÀÖ´Ù.

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â »óÈ£¿¬°á ±â¼ú·Î½á ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» ÀÌ¿ëÇÑ HPCC ¿¡ ¿ä±¸µÇ´Â °í¼öÇà°ú ºñ¿ëÀý°¨Àû ¿¬°á¼ºÀ»

À§ÇÑ Çʿ伺À» º¸¿©ÁØ´Ù. HPCC ¾îÇø®ÄÉÀ̼ǿ¡¼­, G48Ta ¸ðµâÀº ±â°¡ºñÆ® ÀÌ´õ³Ý ¼­¹ö¸¦ À§ÇÑ °í¼öÇàÀ» Á¦°øÇÑ´Ù.

10G4X ¸ðµâÀº 10 ±â°¡ºñÆ® ÀÌ´õ³Ý ¿¬°áÀ» À§ÇØ »ç¿ëµÉ¼öÀÖ´Ù.

 

Single Switch Medium-Sized Network

BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â Áß°ß±â¾÷¿¡°Ô ³×Æ®¿öÅ© ¿ä±¸¸¦ ¿Ïº®È÷ ¸¸Á·½ÃÄÑÁÖ´Â ÀÌ»óÀûÀÎ ´ÜÀÏ ½ºÀ§Ä¡ ¼Ö·ç¼ÇÀ» Á¦°øÇÑ´Ù.

ÀüÇüÀûÀÎ multi-switch ³×Æ®¿öÅ©´Â IP ÅÚ·¹Æ÷´Ï, ¼­ºñ½º¿Í °³¼±µÈ º¸¾ÈÀ» À§ÇÑ ÃÊ°í¼Ó ¼öÇàÀ» À§ÇÑ °í¹Ðµµ PoE ¸¦ Àü´ÞÇÏ´Â ´ÜÀÏ °íÀ̿뼺

½ºÀ§Ä¡¿Í ¿¬µ¿µÉ¼öÀÖ´Ù. G48Te ¿Í G48Pe ¸ðµâÀº ¾îÇø®ÄÉÀ̼ǿ¡¼­ ´Ù¾çÇÑ ÇÏ´ÜÀåºñµéÀ» À§ÇÑ ¿¬°á¼ºÀ» Á¦°øÇÑ´Ù.

 

Traditional Aggregation Layer

Extreme ³×Æ®¿öÅ©´Â two-tier ³×Æ®¿öÅ©°¡ ´õ°£ÆíÇÑ Á¢±ÙÀ̶ó°í ¹Ï´Â ¹Ý¸é¿¡, building or campus or the wiring plant ÀÇ ¼³°è´Â  °¡²û

ÁýÇÕ·¹À̾ ¿ä±¸ÇÑ´Ù. ÀÌ ·¹À̾î´Â ÀüÇüÀûÀ¸·Î ÇϴܽºÀ§Ä¡·Î ºÎÅÍ ±â°¡ºñÆ®³ª 10±â°¡ºñÆ® ¾÷¸µÅ©¸¦ ¸ðÀ¸¸ç, ±â°¡ºñÆ®¿Í 10±â°¡ºñÆ®

ÀÌ´õ³Ý ¾÷¸µÅ©¸¦ ÅëÇÏ¿© Áß¾Ó(¹éº»)À¸·Î ¿¬°áÇÑ´Ù. BlackDiamond 8800 ½Ã¸®Áî ½ºÀ§Ä¡´Â °í¹Ðµµ ±â±âºñÆ®¿Í ÁýÇÕ·¹À̾ ¿ä±¸µÇ´Â

10±â°¡ºñÆ® ÀÌ´õ³ÝÀ» Á¦°øÇÑ´Ù. G48Ta ¿Í G48Xa ±â°¡ºñÆ® ÀÌ´õ³Ý ¸ðµâÀº °í¼öÇà°ú È®À强À» Á¦°øÇÑ´Ù. 10G4X ¸ðµâÀº 10±â°¡ºñÆ®

ÀÌ´õ³Ý ¿¬°á¼ºÀ» À§ÇØ ÀÌ¿ëµÉ¼öÀÖ´Ù.


 

TECHNICAL SPECIFICATIONS
ExtremeXOS V11.5 Supported Protocols
General Routing and Switching
  RFC 1812 Requirements for IP Version 4 Routers
 
RFC 1519 CIDR
  RFC 1256 IPv4 ICMP Router Discovery (IRDP)
  RFC 1122 Host Requirements
RFC 768 UDP
RFC 791 IP
RFC 792 ICMP
 
RFC 793 TCP
  RFC 826 ARP
RFC 894 IP over Ethernet
  RFC 1027 Proxy ARP
  RFC 1866 HTML - Used for web-based Network Login
  RFC 2068 HTTP server - Used for web-based Network Login
RFC 2338 VRRP
RFC 3619 Ethernet Automatic Protection Switching (EAPS) and EAPSv2
IEEE 802.1D - 1998 Spanning Tree Protocol (STP)
IEEE 802.1w - 2001 Rapid Reconfiguration for STP, RSTP
IEEE 802.1s - 2004 Multiple Instances of STP, MSTP
Extreme Multiple Instances of Spanning Tree Protocol (EMISTP)
PVST+, Per VLAN STP (802.1Q interoperable)
Extreme Standby Router Protocol (ESRP)
  IEEE 802.1Q - 1998 Virtual Bridged Local Area Networks
  IEEE 802.1AB - Link Layer Discovery Protocol (LLDP)
LLDP Media Endpoint Discovery (LLDP-MED) ANSI/TIA-1057, draft 08
  Extreme Discovery Protocol (EDP)
  Static Unicast Routes
  Extreme Loop Recovery Protocol (ELRP)
Software Redundant Ports
VLANs, vMANs
IEEE 802.1Q VLAN Tagging
IEEE 802.3ad Static load sharing configuration and LACP based dynamic configuration
IEEE 802.1v: VLAN classification by Protocol and Port
Port-based VLANs
  Protocol-based VLANs
Multiple STP domains per VLAN
Virtual MANs (vMANs)
Quality of Service and Policies
IEEE 802.1D -1998 (802.1p) Packet Priority
RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2598 DiffServ Expedited Forwarding (EF)
RFC 2597 DiffServ Assured Forwarding (AF)
  RFC 2475 DiffServ Core and Edge Router Functions
RIP
  RFC 1058 RIP v1
  RFC 2453 RIP v2
OSPF
  RFC 2328 OSPF v2 (including MD5 authentication)
RFC 1587 OSPF NSSA Option
  RFC 1765 OSPF Database Overflow
  RFC 2370 OSPF Opaque LSA Option
  RFC 3623 OSPF Graceful Restart
BGP4
  RFC 1771 Border Gateway Protocol 4
  RFC 1965 Autonomous System Confederations for BGP
  RFC 2796 BGP Route Reflection (supersedes RFC 1966)
  RFC 1997 BGP Communities Attribute
RFC 2385 TCP MD5 Authentication for BGPv4
"draft-ietf-idr-restart-10.txt (Graceful Restart Mechanism for BGP)"
RFC 2439 BGP Route Flap Damping
RFC 2842 Capabilities Advertisement with BGP-4
RFC 2918 Route Refresh Capability for BGP-4
IPv4 Multicast
RFC 1112 IGMP v1
RFC 2236 IGMP v2
RFC 3376 IGMP v3
IGMP v1/v2/v3 Snooping with Configurable Router Registration Forwarding
IGMP Filters
Static IGMP Membership
Multicast VLAN Registration
RFC 2362 PIM-SM
PIM-DM Draft IETF PIM Dense Mode draft-ietfidmr-pim-dm-05.txt, draft-ietf-pim-dm-new-v2-04.txt
RFC 3569, draft-ietf-ssm-arch-06.txt PIM-SSM PIM Source Specific Multicast
Management and Traffic Analysis
RFC 2030 SNTP, Simple Network Time Protocol v4
RFC 854 Telnet client and server
RFC 783 TFTP Protocol (revision 2)
RFC 951, 1542 BootP
RFC 2131 BOOTP/DHCP relay agent and DHCP server
RFC 1591 DNS (client operation)
RFC 1155 Structure of Mgmt Information (SMIv1)
RFC 1157 SNMPv1
RFC 1212, RFC 1213, RFC 1215 MIB-II, Ethernet-Like MIB & TRAPs
RFC 1573 Evolution of Interface
RFC 1650 Ethernet-Like MIB (update of RFC 1213 for SNMPv2)
RFC 1901 - 1908 SNMP v2c, SMIv2 and Revised MIB-II
RFC 2570 - 2575 SNMPv3, user based security, encryption and authentication
RFC 2576 Coexistence between SNMP Version 1, Version 2 and Version 3
RFC 1757 RMON 4 groups: Stats, History, Alarms and Events
RFC 2021 RMON2 (probe configuration)
RFC 2668 802.3 MAU MIB
RFC 1643 Ethernet MIB
RFC 1493 Bridge MIB
RFC 1354 IPv4 Forwarding Table MIB
RFC 2737 Entity MIB v2
RFC 2233 Interface MIB
RFC 1354 IP Forwarding Table MIB
RFC 2737 Entity MIB, Version 2
RFC 2233 Interface MIB
RFC 3621 PoE-MIB
RFC 1354 IP Forwarding Table MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 1657 BGP-4 MIB

Draft-ietf-idr-bgp4-mibv2-02 .txt-Enhanced BGP-4MIB

draft-ietf-pim-mib-v2-o1.txt
RFC 2787 VRRP MIB
RFC 2925 Ping/Traceroute/NSLOOKUP MIB
Draft-ietf-bridge-rstpmib-03 .txt - Definitions of Managed Objects for Bridges with Rapid Spanning Tree Protocol
Secure Shell (SSH-2) client and server
Secure Copy (SCP-2) client and server
Secure FTP (SFTP) server
sFlow version 5
Configuration logging
Multiple Images, Multiple Configs
BSD System Logging Protocol (SYSLOG), with Multiple Syslog Servers
999 Local Messages (criticals stored across reboots)
Extreme Networks vendor MIBs (includes FDB, PoE, CPU, Memory MIBs) http://www.extremenetworks. com/services/documentation
Security
  Routing protocol MD5 authentication (see above)
  Secure Shell (SSH-2), Secure Copy (SCP-2) and SFTP client/server with encryption/authentication (requires export controlled encryption module)
  SNMPv3 user based security, with encryption/authentication (see above)
RFC 1492 TACACS+
RFC 2138 RADIUS Authentication
RFC 2139 RADIUS Accounting
  RADIUS Per-command Authentication
Access Profiles on All Routing Protocols
  Access Policies for Telnet/SSH-2/SCP-2
  Network Login - 802.1x, web and MAC-based mechanisms
  IEEE 802.1x - 2001 Port-Based Network Access Control for Network Login
Multiple supplicants for Network Login (all modes)
  Fallback to local database (MAC and Web-based methods)
  Guest VLAN for 802.1x
  SSL/TLS transport - used for for web-based Network Login, (requires export controlled encryption module)
  MAC Address Security - Lockdown and Limit
RFC 3046 IP Address Security - DHCP Option 82
IP Address Security - Gratuitous ARP Protection
Layer 2/3/4 ACLs
Denial of Service Protection
  RFC 2267 Network Ingress Filtering
  RPF (Unicast Reverse Path Forwarding) Control via ACLs
  Wire-speed ACLs
  Rate Limiting/Shaping by ACLs
  IP Broadcast Forwarding Control
  ICMP and IP-Option Response Control
  SYN attack protection
CPU DoS Protection with traffic rate limiting to management CPU
Robust against common Network Attacks
  CERT (http://www.cert.org)
  CA-2003-04: "SQL Slammer"
  CA-2002-36: "SSHredder"
  CA-2002-03: SNMP vulnerabilities
  CA-98-13: tcp-denial-of-service
  CA-98.01: smurf
  CA-97.28: Teardrop_Land -Teardrop and "LAND" attack
  CA-96.26: ping
  CA-96.21: tcp_syn_flooding
  CA-96.01: UDP_service_denial
  CA-95.01: IP_Spoofing_Attacks_and_ Hijacked_Terminal_Connections
IP Options Attack
Host Attacks
  Teardrop, boink, opentear, jolt2, newtear, nestea, syndrop, smurf, fraggle, papasmurf, synk4, raped, winfreeze, ping -f, ping of death, pepsi5, Latierra, Winnuke, Simping, Sping, Ascend, Stream, Land, Octopus
IPv6
  RFC 2460, Internet Protocol, Version 6 (IPv6) Specification
  RFC 2461, Neighbor Discovery for IP Version 6, (IPv6)
  RFC 2462, IPv6 Stateless Address Auto configuration - Router Requirements
  RFC 2463, Internet Control Message Protocol (ICMPv6) for the IPv6 Specification
RFC 2464, Transmission of IPv6 Packets over Ethernet Networks
RFC 2465, IPv6 MIB, General Group and Textual Conventions
  RFC 2466, MIB for ICMPv6
   
   


 
  RFC 1981, Path MTU Discovery for IPv6, August 1996 - Router requirements
RFC 3513, Internet Protocol Version 6 (IPv6) Addressing Architecture
  RFC 3587, Global Unicast Address Format
RFC 2710, IPv6 Multicast Listener Discovery v1 (MLDv1) Protocol
  RFC 3810, IPv6 Multicast Listener Discovery v2 (MLDv2) Protocol
  RFC 2740, OSPF for IPv6
RFC 2080, RIPng
RFC 2893, Configured Tunnels
RFC 3056, 6to4
Static Unicast routes for IPv6
Telnet over IPv6 transport
SSH-2 over IPv6 transport
Ping over IPv6 transport
Traceroute over IPv6 transport
 
General Specifications
Switching Capacity
800 Gbps total switching capacity
4.016 Tbps total switching capacity (Including local switching)
570 Mpps Layer 2 HW forwarding rate
570 Mpps Layer 3 HW forwarding rate
Port Capacity
BlackDiamond 8810
36 ports 10GBASE-X (XENPAK) (32 ports if 2 MSMs)
432 ports 10/100/1000BASE-T (384 ports if 2 MSMs)
440 ports 1000BASE-X SFP (Mini-GBIC) (400 ports if 2 MSMs)
BlackDiamond 8806
20 ports 10GBASE-X (XENPAK) (16 ports if 2 MSMs)
240 ports 10/100/1000BASE-T (192 ports if 2 MSMs)
248 ports 1000BASE-X SFP (Mini-GBIC) (208 ports if 2 MSMs)
Management Switch Module
The management module contains both the control path as well as the switch fabric for the BlackDiamond 8800
MSM-G8X BlackDiamond 8800 Management Switch Module, with 8 1000BASE-X mini-GBIC ports
I/O Module Options
G48Te 48-port 10/100/1000BASE-T Gigabit Ethernet module 2:1 oversubscription
G48Pe 48-port 10/100/1000BASE-T Gigabit Ethernet module with PoE 2:1 oversubscription
G48T 48-port 10/100/1000BASE-T Gigabit Ethernet module
G48P 48-port 10/100/1000BASE-T Gigabit Ethernet module with PoE
G48Ta 48-port 10/100/1000BASE-T Gigabit Ethernet module
G24X 24-port 1000BASE-X Gigabit Ethernet module, mini-GBIC modules required
G48Xa 48-port 1000BASE-X Gigabit Ethernet module, mini-GBIC modules required
10G4X 4-port 10GBASE-X 10 Gigabit Ethernet module
XENPAK modules required
  XENPAK options include
  - SR (up to 300 m)
  - LR (up to 50 km)
  - ER (up to 40 km)
- ZR (up to 80 km)
  - LX4 (300m MMF, 10 km SMF)
IEEE 802.3 Standard
G48Te, G48Pe, G48T, G48P and G48Ta Gigabit Ethernet modules comply with the following standards
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-T
IEEE 802.3ab 1000BASE-T
MSM-G8X, G24X and G48Xa Gigabit Ethernet modules comply with the following standard
IEEE 802.3z 1000BASE-X
10GX4 10 Gigabit Ethernet module complies with the following standard
IEEE 802.3ae 10GBASE-X
Power Supply Options
Both AC and DC power supplies are available.
AC power supplies can run from 100Volt to 240Volt, and deliver
  - 700W at 90V to 100V, or
  - 1200W at 200V to 220V
48V DC power supplies deliver 1200W of power
Power over Ethernet (PoE) 802.3af
333 ports with 802.3af class 0 devices supported with 6 power supplies
432 ports with 802.3af class 1 devices supported with 6 power supplies
432 ports with 802.3af class 2 devices supported with 6 power supplies
333 ports with 802.3af class 3 devices supported with 6 power supplies
Physical Specifications
Dimensions
BlackDiamond 8810 Chassis: 24.47¡± high x 17.51¡± wide x 18.23¡± deep (62.2 cm x 44.5 cm x 46.3 cm)
BlackDiamond 8806 Chassis: 17.5¡± high x 17.51¡± wide x 18.23¡± deep (44.45 cm x 44.5 cm x 46.3 cm)
Power Supply: 4.75¡± high x 2.75¡± wide x 13.75¡± deep (12.1 cm x 6.99 cm x 34.9 cm)
MSM Module Dimensions: 1.63¡± high x 15.26¡± wide x 15.25¡± deep (4.1 cm x 38.8 cm x 38.7 cm)
I/O Module Dimensions: 1.63¡± high x 15.26¡± wide x 15.25¡± deep (4.1 cm x 38.8 cm x 38.7 cm)
Weight
BlackDiamond 8810 Chassis: 79 lb (35.8 kg)
BlackDiamond 8810 Chassis fully loaded (max): 200.5 lb (90.9 kg)
BlackDiamond 8806 Chassis: 65 lb (29.5 kg)
BlackDiamond 8806 Chassis fully loaded (max): 151 lb (68.5 kg)
Power Supply: 7 lb (3.2 kg)
MSM-G8X Module: 7.5 lb (3.4 kg)
G48Te Module: 6.75 lb (3.06 kg)
G48Pe Module: 6.75 lb (3.06 kg)
G48T Module: 7.75 lb (3.5 kg)
G48P Module: 8 lb (3.6 kg)
G48Ta Module: 6.75 lb (3.06 kg)
G48Xa Module: 8 lb (3.6 kg)
G24X Module: 7.75 lb (3.5 kg)
10G4X Module: 7.75 lb (3.5 kg)
Power
BlackDiamond 8810 Chassis with Fan Trays: 55 W, 48V, 1.1A (Heat Dissipation: 188 BTU)
BlackDiamond 8806 Chassis with Fan Trays: 45 W, 48V, 1.0 A (Heat Dissipation: 154 BTU)
MSM-G8X Module: 150 W, 48 V, 3.125 A (Heat Dissipation: 515 BTU)
G48Te Module: 105 W, 48V, 2.2 A (Heat Dissapation: 358 BTU)
G48Pe Module: 110 W, 48V, 2.3 A (Heat Dissapation: 375 BTU)
G48T Module: 105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU)
G48P Module: 110 W, 48V, 2.3 A (Heat Dissipation: 375 BTU)
G48Ta Module: 105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU)
G24X Module: 105 W, 48V, 2.2 A (Heat Dissipation: 358 BTU)
G48Xa Module: 105 W, 48V, 2.2 A (Heat Dissipation: 38 BTU)
10G4X Module: 115 W, 48V, 2.4 A (Heat Dissipation: 392 BTU)
 
Operating Specifications
Operating Conditions
Operating Temperature Range: 0° C to 40° C (32° F to 104° F)
Operating Humidity: 10% to 93% relative humidity, non-condensing
Operational Shock: 30 m/s2 (3g), 11ms, 60 Shocks
Operational Sine Vibration: 5-100-5 Hz @ 0.2G, 0-Peak, 0.1 Oct./min.
Operational Random Vibration: 3-500MHz @ 1.5g rms
Regulatory/Safety
North American Safety of ITE
  UL 60950-1:2003 1st Ed., Listed Device (US)
  CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
  CDRH Letter of Approval (US FDA Approval)
NOM/NYCE (Mexico)
  IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE
EN60950-1:2001
  EN 60825-1+A2:2001 (Lasers Safety)
  TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE
CB Report & Certificate per IEC 60950-1:2001+All Country Deviations
AS/NZX 3260 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards
EN 55022:1998 Class A
EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11
EN 61000-3-2,3 (Harmonics & Flicker)
ETSI EN 300 386:2001 (EMC Telecommunications)
89/336/EEC EMC Directive
International EMC Certifications
CISPR 22:1997 Class A (International Emissions)
CISPR 24:1997 Class A (International Immunity)
IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A
IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A
IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A
IEC/EN 61000-4-5 Surge, 2kV, 4kV, Criteria A
IEC/EN 61000-4-6 Conducted Immunity
IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A
IEC/EN 61000-4-11 Power Dips & Interruptions, > 30%, 25 periods, Criteria C
Country Specific
VCCI Class A (Japan Emissions)
AS/NZS 3548 ACA (Australia Emissions)
CNS 13438:1997 Class A (BSMI-Taiwan)
MIC Mark, EMC Approval (Korea)
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications)
ETSI EN 300 019 (Environmental for Telecommunications)
IEEE 802.3 Media Access Standards
IEEE 802.3z 1000BASE-X
IEEE 802.3ab 1000BASE-T
IEEE 802.3ae 10GBASE-X
IEEE 802.3af Power over Ethernet
Environmental Standards
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5G
 
Warranty
1-year on Hardware
90-days on Software
   


Ordering Information
Part Number Description
41011 BlackDiamond 8810 10-Slot Chassis including Fan Tray
41012 BlackDiamond 8806 6-Slot Chassis including Fan Tray
60020 BlackDiamond 10808/BlackDiamond 8800 700W/1200W 100-240V PSU
60021 BlackDiamond 10808/BlackDiamond 8800 1200W -48V DC PSU
41211 BlackDiamond 8800 Management Switch Module, w/8 1000BASE-X
mini-GBIC I/O Ports
41511 BlackDiamond 8800 48-port 10/100/1000BASE-T RJ-45
41512 BlackDiamond 8800 48-port 10/100/1000BASE-T PoE RJ-45
41513 BlackDiamond 8800 48-port 10/100/1000BASE-T RJ-45 2:1 Oversubscription, Edge
41514 BlackDiamond 8800 48-port 10/100/1000BASE-T PoE RJ-45 2:1 Oversubscription, Edge
41515 BlackDiamond 8800 48-port 10/100/1000BASE-T RJ-45, Advanced Aggregation
41541 BlackDiamond 8800 24-port 1000BASE-X mini-GBIC
41542 BlackDiamond 8800 48-port 1000BASE-X mini-GBIC, Advanced Aggregation
41611 BlackDiamond 8800 4-port 10GBASE-X XENPAK
41111 BlackDiamond 8810 Spare Fan Tray
65043 BlackDiamond 8806 Spare Fan Tray
41112 BlackDiamond 8800 Spare PSU/Fan Controller Board
41121 BlackDiamond 8800 Spare Blank Panel
41141 BlackDiamond 8810 Mid Mount Kit
41151 BlackDiamond 8800 Cable Management Kit
41311 BlackDiamond 8800 ExtremeXOS Core Software Upgrade
10110 10 Gigabit Ethernet XENPAK Transceiver, 850 nm, up to 300 m on Multimode Fiber, SC Connector
10111 10 Gigabit Ethernet XENPAK Transceiver, 1310 nm, up to 10 km on Single-mode Fiber, SC Connector
10112 10 Gigabit Ethernet XENPAK Transceiver, 1550 nm, up to 40 km on Sngle-mode Fiber, SC Connector
10113 10 Gigabit Ethernet XENPAK Transceiver, 1550 nm, up to 80 km on Single-mode Fiber, SC Connector
10114 10 Gigabit Ethernet WWDM XENPAK Transceiver, 1310 nm, up to 300 m on Multi-mode Fiber and up to 10 km on a Single-mode Fber, SC Connector
10051 Mini-GBIC, SFP, 1000BASE-SX, LC Connector
10052 Mini-GBIC, SFP, 1000BASE-LX, LC Connector
10053 Mini-GBIC, SFP, Extra Long Distance SMF 70 km/21 dB Budget, LC Connector
10056 Mini-GBIC, SFP, 1000BASE-BX-U, SMF (1490 nm TX/1310 nm RX Wavelength)
10057 Mini-GBIC, SFP, 1000BASE-BX-D, SMF (1310 nm TX/1490 nm RX Wavelength)
10060 Mini-GBIC, SFP, Dual-speed 100 FX/1000LX, LC Connector